Balboa Water Group Servicing Slimline Air Control 10-2310 One Inch 10-2510 One Half Inch User Manual

Servicing of the slimline air control

Advertising
background image

88-4040 Rev C June 30, 2009

TO DISASSEMBLE:

Align window on the handle (#7) with the

1.

“MIN” position. Place the palm of the hand
against the top of the Slimline Air Control
handle (#7), and press down firmly, rotating
the handle counterclockwise about a
quarter turn.
Grasp the outer edges of the Handle with

2.

your fingertips and pull the Handle away from
the tub. The Slimline Air Control Handle/
Stem Assembly (#8) should come out freely
from the Outer Body (#3).
At this point, the entire Air Stem Assembly

3.

(#8) may be replaced. If further disassembly is
needed, go to the next step.
Once the Air Stem Assembly is removed,

4.

locate the rectangular slots on the Inner Body
(#5) and place your thumb and index fingers
90° to the slot on the opposite sides. Your
fingers should be against the underside of
the Handle (# 7).
In a pinching motion, squeeze the top of

5.

the Inner Body (# 5). With your thumb and
index fingers still in place, pull the Inner
Body (#7) away from the Handle Assembly.
Squeezing firmly should release the latches
on the Inner Body to free it from the Handle
Assembly (#7).
Once the Inner Body is detached, the Seal

6.

(#6) can be removed from the inside of the
Inner Body and all pieces may be serviced.

TO REASSEMBLE:

Make sure handle/stem assembly (#8) is

1.

in the fully closed position by aligning the
window on the inner body (#5) and making
sure the foam is not showing. Insert handle/
stem assembly (#8) into outer body (#3)
with the window on the handle (#7) in the
“MAX” position.
Once the handle/stem assembly (#8) is in the

2.

outer body (#3), press on the top surface of
the handle (#7) firmly, and rotate the handle
clockwise until it stops (approx. 1/4 turn).

NOTE: IF RE-LUBRICATION IS NECESSARY,
USE ONLY A SILICONE BASED LUBRICANT!

DO NOT USE ANY TYPE OF PETROLEUM
BASED LUBRICANTS ... THEY WILL CAUSE
PRODUCT FAILURE.
Check the MAX and MIN position through

3.

the window on the top of the handle, and
match with the operation of the jets. If
aeration occurs in the “MIN” position, the
Slimline Air Control has been improperly
assembled. To correct, press down firmly
on the handle and rotate again clockwise.
Recheck the “MAX/MIN” position with the
operation of the jets.

SERVICING OF THE SLIMLINE AIR CONTROL

P/N 10-2310 1” SLIMLINE AIR CONTROL

P/N 10-2510 1/2” SLIMLINE AIR CONTROL

PART # FOR

10-2310

PART # FOR

10-2510

DESCRIPTION

1

10-3706

10-2205 NUT

2

10-3705 10-2204

GASKET

3

30-2316

30-2516

SLIMLINE OUTER BODY

4

30-2315

30-2515

SLIMLINE CHECK VALVE BALL

5

30-2313

30-2513

SLIMLINE INNER BODY

6

30-2314 30-2514

SEAL

7

30-2311

30-2517

SLIMLINE HANDLE W/ROTOR

8

10-2319

10-2519

SLIM LINE STEM ASSEMBLY

#7

#1

#1

#4

#4

#6

#8

#2

#2

#5

#3

#3

Advertising