Balboa Water Group Gunite Micro'ssage 10-4562 User Manual

Balboa Water Group Accessories for water

Advertising
background image

GUNITE MICRO’SSAGE (16-5275) / CONVERTA’SSAGE (10-4562)

INSTALLATION INSTRUCTIONS

1) Plumb 10-4320 (# 1) Venturi Tee at desired location.

NOTE: Unit must be installed at least 8 inches below water level with Venturi Tee secured to steel, and

installed

straight.

2) Install Pressure Test Cap or Plug into Venturi Tee.

3) Shoot gunite leaving an open area around pipe approximately 4-1/2” deep x 6-1/2” wide.

(These dimensions are from intended plaster finish.)

NOTE: Proper care should be taken to maintain an adequate wall thickness to provide for structural

support of jet assembly.

4) After pressure test, remove Cap or Plug from Venturi Tee.

5) The exposed pipe (Venturi Tee Barrell) needs to be cut back approximately 2-3/4” from intended

plaster finish. This is to allow 10-4332 (#3) Gunite Niche Adapter to be recessed the proper distance

into the wall. (The outer edge of the 10-4332 Niche Adapter should finish exactly even with plaster.)

NOTE: Remove nozzle from tee when cutting tee to proper length. After cutting tee to proper length,

cut nozzle, if necessary, to assure distance behind back of eyeball is between 1/2” - 1“.

Reinstall nozzle in tee.

6) Glue 10-4322 (#3) Gunite Niche Adapter to exposed Venturi Tee Barrell using a P.V.C. cement.

7) Thread 10-4333 (#6) Gunite Niche Adapter Test Plug into Niche Adapter. This will keep plaster and

other debris out of niche.

NOTE: 10-4333 (#6) Test Plug can be used again on future installations.

8) Fill-in behind 10-4332 (#3) Niche Adapter and plaster flush to outer edge.

9) Remove 10-4333 (#6) test plug from 10-4332 (#3) Niche Adapter.

10) Install 16-5215 (#4) fitting with bearing into 10-4332 (#3) Niche Adapter. (H.A.I. recommends the use of

silicone to secure fitting.)

11) For best results adjust the length of 10-4401T (#2) Twist Lock Gunite Nozzle to be within 3/4” to 1”

of the back of fitting 16-5215 (#4).

12) Install either a 16-5230 (#5) Grill and Flowpath Assembly or a 10-4505 (#7) Stationary Escutcheon

Assembly into fitting 16-5215 (#4). (Both assemblies twist lock onto fitting.)