Balboa Water Group Hand Held Jet For Hydro Jet, Micro Jet, Slimline Jet, Mlcro'ssage Converta'ssage User Manual

Balboa Water Group Accessories for water

Advertising
background image

HAND HELD JET INSTRUCTIONS

for Hydro Jet / Micro Jet / Slimline™ Jet

Micro’ssage / Converta’ssage

1. Turn off circulation pump.
2. Remove the therapy option from any of the Converta’ssage or Micro’ssage Jets, or remove

the eyeball from the Hydro, Micro or Slimline™ Jet.

3. Remove the nozzle from inside the jet, by turning it counter-clockwise. (A 9/16” nut driver

or a 9/16” socket on a ratchet extension will allow easy removal of the nozzle from the

Hydro Air Jets.)

4. Install the Hand Held Jet Adapter (#1) by threading it into the opening from which the nozzle
was

removed.

NOTE: There are TWO DIFFERENT sets of threads on the adapter.

1. The first set screws into the Hydro, Micro & Slimline™ Jets. If you are installing the

Hand Held Jet (#3) into one of these jets, simply thread the adapter into the

orifice

threads.

2. The second set of threads fit the Converta’ssage® and Micro’ssage® Jets. If you need

to adapt your Hand Held Jet to one of these models, you must cut the first set of

threads off with a PVC cutter or a hacksaw. Remove any plastic burrs that remain.

5. The hole on the float (#2) must be above the water level to draw air.
6. Start the circulation pump.
7. Squeeze the trigger (#4) to start the Hand Held Jet (#3) and release the trigger

(#4) to stop it.

TO CHANGE THERAPY OPTION IN HAND HELD JET:

Insert cage and eyeball (#5) (or flowpath, #6) into Hand Held Jet (#3) by pressing firmly

to snap into place.

CONTACT YOUR RETAILER OR SPA MANUFACTURER FOR OTHER THERAPY OPTIONS.

#1 Hand Held Jet Adapter
#2 Float
#3 Hand Held Jet
#4 Trigger
#5 Cage & Eyeball
#6 Flowpath

88-4047, Rev. A June 1, 2009

Advertising