Step 7 apply nyogel & plug n’ click click – Balboa Water Group Plug N' Click Heater On An Older Spa System User Manual

Page 2

Advertising
background image

PLUGNCLICK 06/24/2014
©2014 Balboa Water Group. Single Source Solution. All rights reserved.
1382 Bell Avenue | Tustin, CA 92780 | p 714.384.0384 | www.balboawater.com
We reserve the right to change technical data without further notice.
42269_A

STEP 7 APPLY NYOGEL &

PLUG N’ CLICK

CLICK

Cable 25263

Cable 25696

– Attach the Heater Adapter Cable (25696) onto the circuit board (where the copper straps were attached).
– Use a torque wrench to tighten the 2 nuts to manufacture specification. Example the system above shows the

specification as 30-35 lb inch. Then, add 1 drop of Loctite to each nut to seal.

– Place your new heater into the heater rack. Insert the
2 heater sensors and tighten the 2 heater nuts.

STEP 5 INSTALL HEATER CABLES AND TORQUE TO MANUFACTURE SPECIFICATION

STEP 6 INSTALL NEW HEATER AND TIGHTEN THE 2 NUTS

Note: Torque specifications shown above.

Apply NYOGEL 760G here.

Applying NYOGEL

Here

– Use a flat stick apply NYOGEL 760G to all 3 sides of the heater power male

and female terminals.

– Plug N’ Click the 2 cables. Place the cover back on and tighten the 2 screws.

Apply Loctite Here