256 GPM Suction Flow Installation Instructions

Packaging and Installation Instructions - SAVE INSTRUCTIONS

For multiple drain use only in self-contained factory manufactured spas.

1.

Do not try to locate suction outlets on seating areas or on the brackets for such seating areas.

2.

When two or more suction fittings are used on a common suction line they shall be separated by a minimum of 3 ft. (91.44 cm);

3.

or, if any are located closer, they shall be located on two different planes (i.e., one each on two separate vertical walls).
Confirm with local and national codes and standards for proper installation.
In the event of one suction outlet being completely blocked, the remaining suction outlets serving that system shall have a flow

4.

rating capable of the full flow of the pump(s) for the specific suction system.
Maximum flow rating with head loss curve: 256 GPM with vacuum tube.

5.

Acceptable connecting pipe size(s) - maximum 2.5” dia.

6.

Mounting position: wall only

7.

Suction outlet part number 30240-U applicable.

8.

Part numbers for 256 GPM configuration: (Replace within seven installed years)

9.

30240U-XX VGB 2008 256 / 179 GPM suction cover & Screw/UV
30341 VGB 2008 256GPM Buttress suction wall fitting x custom slip
30167-V 2” SPG x Custom SPG x 3/4” smooth barb vacuum tube adapter
30169-V 2.5” SPG x Custom SPG x 3/4” smooth barb vacuum tube adapter
30234-V Suction L gasket use 3.75” hole size
30236-V Suction flat gasket use 3.63” hole saw
30239-V Suction nut
30238-V Compensating ring
63414 3/4” ID x 1” OD Tubing 8ft long
Tools required: Philips screw driver, glue for plumbing connections, clamp & pliers for tubing connections.

10.

Service and winterizing instructions.

11.

a. Service - remove screw. Remove cover. Place suction cover on wall fitting with blank portion, no holes pointed down.
The keyway on inside cover must match the notch on the wall fitting. Insert stainless steel screw in cover and tighten
securely. Do not overtighten (as plastic will strip).
b. Winterizing - Drain suction line thoroughly and blow out all remaining water. See spa manufacturer instructions
for

winterizing.

WARNING: Do not exceed the maximum allowable flow rate stated on the suction fitting.

12.

The suction fitting including fasteners should be observed for damage or tampering before each use of this facility.

13.

Note: Missing, broken, or cracked suction fittings shall be replaced before using this facility. Loose suction fittings shall be
reattached or replaced before using this facility. Read, then keep these instructions for future reference.
Caution: Be aware that changing pump types and sizes can increase flow rate. The maximum flow rate is 256
GPM with vacuum tube.