Balboa Water Group VGB 2008 124 GPM Suction Flow User Manual

Instructions

Advertising
background image

VGB 2008

124 GPM Suction Flow

Installation Instructions

For single or multiple use submerged suction outlet.

1.

Do not try to locate suction outlets on seating areas or on the brackets for such seating areas.

2.

When two or more suction fittings are used on a common suction line they shall be separated by a minimum of 3 ft. (91.44 cm), or

3.

if any are located closer they shall be located on two different planes (i.e., one each on two separate vertical walls). Confirm with
local and national codes and standards for proper installation.
In the event of one suction outlet being completely blocked, the remaining suction outlets serving that system shall have a flow

4.

rating capable of the full flow of the pump(s) for the specific suction system.
Maximum flow rating with head loss curve: 124 GPM.

5.

Acceptable connecting pipe size(s) - maximum 2.0.”

6.

Mounting position: wall only.

7.

Suction outlet part number 30173U applicable.

8.

Part numbers:

9.

30173U-XX VGB 2008 124 GPM SUCTION COVER & SCREWS/UV (replace within seven installed years)
30147-V VGB 2008 SUCTIONS ALL FITTING (replace within seven installed years)
30115-V SUCTION FLAT GASKET (replace within seven installed years)
30160-V 2”SPG X 1/2” SOCKET SAFETY SUCTION ADAPTER (replace within seven installed years)
Tools required: Philips screw driver, glue for plumbing connections, clamp & pliers for tubing connections.

10.

Service and winterizing instructions:

11.

a. Service - remove screw. Remove cover. Place suction cover on wall fitting with blank portion, no holes pointed down.
The keyway on the inside cover must match the notch on the wall fitting. Insert stainless steel screw in cover and tighten
securely. Do not overtighten (as plastic will strip).
b. Winterizing - Drain suction line thoroughly and blowout all remaining water. See spa manufacturer instructions
for

winterizing.

WARNING: do not exceed the maximum allowable flow rate stated on the suction fitting.

12.

The suction fitting including fasteners should be observed for damage or tampering before each use of this facility.

13.

Note: Missing, broken, or cracked suction fittings shall be replaced before using this facility. Loose suction fittings shall be
reattached or replaced before using this facility. Read, then keep these instructions for future reference
Caution: Be aware that changing pump types and sizes can Increase flow rate. The maximum flow rate is 124 GPM.

Instructions

40751 Rev A May 21, 2012

Advertising