How to use, Specifications, Limited warranty – CatEye Hl-EL920RC [Sumo 2] User Manual

Page 5: Aswitch operation (switching the lighting mode), Temperature control, Remaining battery level, Bhow to charge battery unit

Advertising
background image

5

HOW TO USE

A

Switch operation (switching the lighting mode)

Use the switch of the light unit to turn on/off and to switch the lighting mode.

Press and hold” the switch to turn on/off the power (light on/off).

The flash mode can be triggered even with the light turned off.

*

Switching operation Lighting mode Brightness Mode indicator Operating time

Press

Dynamic

Green

Approx. 1.5 hours

Normal

Orange

Approx. 4 hours

All night

Red

Approx. 10 hours

Quick double press

Flash

None

Approx. 35 hours

Mode indicator

:

*

Immediately after switching the lighting mode, the switch flashes

for 5 seconds and indicates the current lighting mode.

Mode memory function (

*

*2) : The light unit turns on at the previous mode.

Temperature control

When the light unit becomes hot while it is turned on in the dynamic mode, the protection

function switches automatically to the normal mode. In such a case, it returns to the pre-

vious dynamic mode when the light unit becomes cooler by air-cooling effects, etc.

When the light unit increases in temperature abnormally, its safety function

*

becomes active and turns off the light. When it decreases in temperature, it can

be turned on again by switch operation. It is recommended to use in the All night

mode when there is no wind, e.g., when you are not riding.

Remaining battery level

When the light unit is on, the color of the switch shows how much battery power remains.

Guideline for the battery indicator

Green light : The remaining battery level is sufficient.

Orange light : The remaining battery level is low. Charge the battery unit.

Red light

: Stop using the light unit, and charge the battery unit.

The indicator is only an estimation of the remaining battery run-time, and

*

varies with the environment or conditions of use.

Make it a habit to charge the battery unit when the indicator changes to orange.

*

Low battery charge warning function

To prevent the light unit from being turned off unexpectedly due to low battery

charge, this function turns on the indicator red, and switches the lighting mode

from normal lighting to intermittent flashing.

B

How to Charge Battery unit

Important!

If the battery unit is wet, wipe dry with a dry cloth before charging the batteries.

Be sure to use only the supplied battery charger (applicable to 100 - 240 volts).

The battery charger is indoor use only.

When the charging indicator of the battery charger flashes green, there may

be a circuit failure. Unplug the charger and remove the cause.

When the charging indicator of the battery charger flashes green quickly

within a few minutes after charging starts, unplug the charger from the

outlet, and charge the battery again according to the procedure.

Similar behavior may be seen when the battery is hot immediately after use.

Charge the battery unit after cooling it sufficiently.

When the same results occur repeatedly, the battery may be deteriorated.

When the battery unit repeatedly does not meet the proper operating time even

though it is fully charged, it might be at the end of its operating life. Replace

the old battery unit with a new one.

Lithium-ion rechargeable batteries are recyclable. Remove the used batteries from the

battery unit, apply insulating tape on the plug, and take them to stores supporting recharge-

able battery recycling (refer to “How to disassemble the battery unit (for disposal)”).

The battery charge can be checked with the charging indicator of the battery charger.

*
Charge the battery unit with the following procedure.

Plug the battery charger to an AC outlet.

1

Check that the charging indicator flashes red three times as the power lamp

*

turns red.The power lamp turns red while the unit is connected to an outlet.

Connect the plug of the battery charger to the plug of the battery unit.

2

Charge the batteries with the plug locked.

*

When the charging indicator continues flashing red, disconnect the unit and

*

then re-connect it according to the specified procedure.

When charging is complete, the indicator light changes from red to green.

*

3

After charging is complete, make sure to unplug the charger from the AC outlet.

Charging indicator state

Standard charging time

Red light : Charging

Approx. 5 hours

Green light : Charging is completed
Flashing red light / Flashing green light : Charge error
The standard charging time and run time are guideline values and depend on

*

the operating environment.

The supplied BA-904 battery unit (4600 mAh) is charged with about 80% of its

*

capacity in 2.5 hours after charging starts.

Directly connect the battery unit to the battery charger to charge, without using

*

the extension cable. Doing so may extend the charging time.

SPECIFICATIONS

Light source .........................................Multichip white LED (x2)

Battery unit ..........................................Lithium-ion rechargeable battery BA-904 Li-ion/7.4V 4600mAh

Battery charger ....................................CHR-001 Li-ion (AC100V - 240V 50/60Hz)

Operating time .....................................Dynamic: Approx. 1.5 hours, Normal: Approx. 4 hours,

All night: Approx. 10 hours, Flash: Approx. 35 hours

The optional BA-908 doubles the operating time.

*

Standard charging time ........................Approx. 5 hours (Optional BA-908: Approx. 10 hours)

Temperature range ...............................Charging: 5°C - 40°C, Operating: -10°C - 40°C

Recharge/discharge number of times ...About 300 times (until the rated capacity drops to 70%)

The specifications and design are subject to change without notice.

*

2-8-25, Kuwazu, Higashi Sumiyoshi-ku, Osaka 546-0041 Japan

Attn: CATEYE Customer Service Section

Phone : (06)6719-6863

Fax

: (06)6719-6033

E-mail : [email protected]

URL

: http://www.cateye.co.jp

CO.,LTD.

Service & Research Address for USA

CATEYE Service and Research Center

1705 14th St. 115 Boulder, CO 80302

Phone : 303.443.4595

Toll Free : 800.5CATEYE

Fax

: 303.473.0006

E-mail : [email protected]

URL

: http://www.cateye.com

LIMITED WARRANTY

2-year Warranty: Light unit / Battery unit /Battery charger (Deteriora-

tion of the battery is excluded.)

CatEye products are warranted to be free of defects from materials and

workmanship for a period of 2 years from original purchase. If the product

fails to work during normal use, CatEye will repair or replace the defect at no

charge. Service must be performed by CatEye or an authorized retailer. To

return the product, pack it carefully and enclose the warranty certificate (proof

of purchase) with instruction for repair. Please write or type your name and

address clearly on the warranty certificate. Insurance, handling and transporta-

tion charges to CatEye shall be borne by person desiring service. For UK and

REPUBLIC OF IRELAND consumers, please return to the place of purchase. This

does not affect your statutory rights.

Advertising