Installation

Motor Installation

To prevent damage to the fan during shipping, motors 5 HP

and larger, and extremely heavy motors (cast iron or severe
duty) are shipped loose and must be field mounted by bolting
the motor on the motor mounting plate in the existing mounting
slots.

KSP Assembly

NFPA 96 installation guidelines for KSP fans are shown in

figure 1 and 2 on page 2.

a. Remove the top cap (item 3) from the fan.
b. Remove the intake hood (item 2) and the filter(s) (item 1)

from the inside of the fan.

c. Replace the topcap.
d. Slide the intake hood over the flange on the fan and

secure with the nine screws provided.

e. Remove the two thumb screws and the filter retainer.
f. Slide the filter(s) down between the angles inside the

intake hood and the flange on the front of the hood.

g. Replace the filter retainer and secure with the two thumb

screws.

h. Caulk the top of the intake hood where the hood meets

the fan. Use an appropriate caulk for exterior use.

Centrifugal Filtered Supply Fans

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

ASP/KSP

This publication contains the installation, opera-

tion and maintenance instructions for standard
units of the ASP/KSP-Centrifugal Filtered Supply
Fans
.

Carefully read this publication prior to any instal-

lation or maintenance procedure.

Loren Cook catalog, ASP/ASP-T and KSP, provides

additional information describing the equipment, fan
performance, available accessories, and specification
data.

For additional safety information, refer to AMCA pub-

lication 410-96, Safety Practices for Users and Install-
ers of Industrial and Commercial Fans
.

All of the publications listed above can be obtained

from Loren Cook Company by phoning 417/869-6474,
extension 166; by FAX at 417/832-9431; or by e-mail at
[email protected].

For information on special equipment, contact Loren

Cook Company Customer Service Department at 417/
869-6474.

Receiving and Inspection

Carefully inspect the fan and accessories for any

damage and shortage immediately upon receipt of the
fan.

• Turn the wheel by hand to ensure it turns freely and

does not bind.

• Inspect dampers (if supplied) for free operation of

all moving parts.

• Record on the Delivery Receipt any visible sign of

damage.

Handling

Lift the fan by the base or lifting eyes. Never lift by the

shaft, motor, or housing.

Storage

If the fan is stored for any length of time prior to

installation, store the fan in its original crate and protect
it from dust, debris and the weather.

WARNING

This unit has rotating parts. Safety precautions

should be exercised at all times during installation,
operation, and maintenance.
ALWAYS disconnect power prior to working on fan.

ASP