Merrychef eikon e4 User Manual

Page 33

Advertising
background image

Service & Parts Manual original Instructions

Part Number 32Z3813 US

Issue 1

33

TESTING

COMPONENT

S

A

A

Soak Test

15.8

Checking the oven cavity integrity.
Procedure:

Place an oven/microwave safe container with

15.8.1
approx. 2 litres of water into the oven.

Close the oven door and select ‘Soak Test’ (A)

15.8.2
from the Service mode oven tests (maximum oven
temperature, 50% microwave power, maximum fan
speed).

Run the test (30 minutes), carefully checking the

15.8.3
oven casing, joints and door seal for signs of steam or
water escaping from the oven cavity.

If necessary, rectify any leaks and repeat the test.

15.8.4

Safely remove the container from the oven.

15.8.5

Recommission Test

15.9

The Recommission tests are performed following

the completion of a service or repair to ensure

the oven is operational before handing back to

the customer.
Some of the tests have a countdown timer where

failing to carry out a test within the time limit will

cause a test failure and the Recommission test will

have to be restarted.
Procedure:

Select ‘Recommission Test’ (A) from the service

15.9.1
mode oven tests and follow the on screen instructions
to perform the tests. Do not select the red ‘X’unless
you want to stop the test.

After a test has successfully passed, select OK to

15.9.2
continue.

When all the tests have been successfully

15.9.3
performed the display shows the Recommission test
has passed, select OK to confirm.

In the event of a Recommission test failure,

15.9.4
the detail will be recorded in the Error log. Any error
should be rectified and the Recommission test run
again.

Advertising