3.4 OPTIONAL WALL SWITCH / THERMOSTAT

For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient
location. Route a 2 strand, solid core millivolt wire from the valve to the wall switch or millivolt thermostat. The
recommended maximum lead length depends on wire size:

WIRE SIZE

MAX. LENGTH

14

gauge

100

feet

16 gauge

60 feet

18 gauge

40 feet

Disconnect the existing wires from terminals 1 and 3 (from the
ON/OFF switch) and replace with the leads from the wall switch / millivolt thermostat.

50.1

3

1

2

!

WARNING

DO NOT CONNECT EITHER THE WALL SWITCH, THERMOSTAT OR GAS VALVE DIRECTLY TO 110

VOLT ELECTRICITY.

3.5 MOBILE HOME INSTALLATION

29.2

Suitable for mobile home installation where the mobile home has been permanently placed on its site.
This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where
not prohibited by local codes.
For mobile home installations, the appliance must be fastened in place. It is recommended that the appliance
be secured in all installations. See “REPLACEMENTS” section for the levelling / securing kit specifi c to your
appliance.