NOVA™ HEATED

REACH-INS, PASS-THRUS & ROLL-INS

Installation, Operation and

Maintenance Instructions

INSPECTION

When the equipment is received, all items should be carefully checked against the bill of lading to
insure all crates and cartons have been received. All units should be inspected for concealed damage
by uncrating the units immediately. If any damage is found, it should be reported to the carrier at
once, and a claim should be filed with the carrier. This equipment has been inspected and tested in
the Nor-Lake Manufacturing Facility and has been crated in accordance with transportation rules and
guidelines. Manufacturer is not responsible for freight loss or damage.

INSTALLATION

GENERAL

Remove the unit crate and base. For the Reach-In and Pass-Thru models, locate the casters or legs
found in the interior of the cabinet. (Not applicable for Roll-In models). Attach the casters or legs to
the unit base by screwing them into the same threaded fittings that were used to secure the crate
base to the cabinet. Insure that the casters or legs are screwed all the way into the base.

Once the cabinet is placed in its permanent location, the cabinet should be leveled from side to side
and front to back. If necessary, to level Reach-In and Pass-Thru models with casters, washers can be
placed on the threaded fitting before attaching the caster to the cabinet. Loosening a caster, so that it
is not screwed tightly to the base, should not be used as a means to level the cabinet. For those
models with legs, an adjustable style leg is used for leveling purposes. There are no provisions for
easily leveling the Roll-In models except by the use of shims. Only minimal shimming is allowable.
After a Roll-In model is leveled, it is required by NSF that the cabinet be sealed to the floor with an
approved sealant such as Dow Corning #732 silicone to prevent any contaminants from collecting
under the unit. Refer to Table 1 for complete physical specifications.

If the doors are out of alignment on the cabinet, the doors can be adjusted. Opening the door(s) and
loosening the screws that hold both the top and bottom hinges to the cabinet can accomplish this.
After adjusting the door so that it is aligned correctly, tighten the screws to securely hold the hinges in
place.

Table 1 - Physical Specifications

Unit

Refrigerant

Model

Exterior Dimensions W x D x H

Type/Amount

NW211

27-1/2" x 34-7/8" x 81-1/2" *

See Serial Tag

NW482

55" x 34-7/8" x 81-1/2" *

See Serial Tag

PW252

27-1/2" x 37-3/4" x 81-1/2" *

See Serial Tag

PW554

55" x 37-3/4" x 81-1/2" *

See Serial Tag

PWW332

31-3/4" x 38-3/4" x 84-3/4"

See Serial Tag

PWW724

63-1/2" x 38-3/4" x 84-3/4"

See Serial Tag

* Dimensions reflect height with casters. Height with legs is 82-3/4". Roll-In models reflect height

of cabinet.