Nor-Lake AdvantEDGE Chef Base User Manual

Nor-Lake Refrigerators

Advertising
background image

08/13 Rev. E 147774

1

CHEF BASE CABINETS

Installation, Operation and Maintenance Instructions

INSPECTION

When the equipment is received, all items should be carefully checked against the Bill
of Lading to ensure all crates and cartons have been received. Do not sign the freight
bill clear until the freight has been properly inspected for damage. All units should be
inspected for damage including concealed damage by uncrating immediately. If any
damage is found, it should be reported to the carrier at once, noted on the Bill of Lading
and a claim should be filed with the carrier. This equipment has been inspected and
tested in the manufacturing facility and has been crated in accordance with
transportation rules and guidelines. The manufacturer is not responsible for freight loss
or damages.

INSTALLATION

The exterior top of the cabinet has been protected by a plastic covering. Peel this
protective covering before installation. After removing the covering, clean the interior
and exterior surfaces of the unit with soap and water and a rinse with clean water. Do
not use chlorinated cleaners on the surfaces as they can cause corrosion.

The refrigeration system located on the side of the unit requires free air access for
proper operation. Allow a minimum of seven inches between the back of the cabinet
and the wall. The equipment is designed to accept heat generating cooking equipment if
the equipment is properly installed with legs (supplied by the cooking equipment
manufacturer). A minimum clearance of 4 inches is required between the bottom of the
cooking equipment heating element and the cabinet top. Failure to provide adequate
clearance voids manufacturer warranty. Installation of a heat shield (supplied by others)
is recommended for optimum performance.

Confirm that the proposed electrical outlet has the correct voltage, frequency and
current carrying capacity for the requirements of the unit. This information is noted on
the data plate on the inside left wall of the unit. The unit should be isolated on a circuit.
Do not use an extension cord to get power to the unit. Improper electrical installations
will void the compressor warranty. To prevent shock and fire, be sure the unit is properly
grounded.

The temperature controller is located inside the refrigerated compartment in the back
right top corner. The default temperature is set at “normal”. Adjust the temperature to fit
your needs. It is not recommended that the cabinet be run colder than +35°F.