Pitco Frialator Digital Thermostat User Manual

Rethermalizer digital thermostat

Advertising
background image

RETHERMALIZER

DIGITAL THERMOSTAT

PROGRAMMABLE FUNCTIONS

Differential temperature - Sets the temperature range above and below the
set temperature that the heating system cycles on and off

Maximum controller temperature - Sets the maximum temperature that can
be programmed into the controller

Minimum controller temperature - Sets the minimum temperature that can be
programmed into the controller

Calibration range - Enables calibration corrections to be made between
actual temperature and sensed temperature at the probe

Set temperature mode - Set temperature is programmed in this mode

Press , Display will show “SP1
(Set temperature mode - Set temperature is programmed in this mode)

Press , Display will show “XXX” (XXX = current set temperature)

Press to change temperature setting (NOTE: If set temperature will
not adjust to desired setting, check HI and LO temperature settings)

A JUMPER WIRE MUST BE INSTALLED BETWEEN TERMINALS +5 AND -3 ON THE
BACK OF THE CONTROLLER. CONTROLLER IS NON-PROGRAMMABLE WITHOUT
JUMPER WIRE INSTALLED

*

*

*

*

*

DF1

HI

LO

CAL

SP1

ENTERING PROGRAMMING MODE

PROGRAMMING SET TEMPERATURE

*

*

*

SET

SET

*

Press SET to save new temperature setting

180

ADJUST

F

SET

SET MODE

HIDDEN

PROGRAM

L20-283 rev 0