INSTALLATION

SSPE14: Floor Model Electric Pasta Cooker

3 L20-339, rev.02 (08/11)

WARNING

DO NOT install this appliance next to a deep fat fryer. A splash over of water into the hot oil may
cause a flash fire.

WARNING

DO NOT obstruct the flow of ventilation or air openings around the appliance. Adequate
clearance around the appliance is necessary for servicing and proper component ventilation.
Ensure that you meet the minimum clearance requirements specified in this manual.

WARNING

When water is at a high temperature and high pressure, excessive splashing of hot water
may occur that could result in injury.

Measured

Max Limit or Range

OK

Temperature

180°F (82°C) Max.

Hardness

2.0 Grains/Gal. Max.

pH

6.5 to 8.0

Pressure

20 psi (138 kPa) to 60 psi (414 kPa)

Water Quality Checklist

1.2. INSTALLATION

CLEARANCES

The clearances shown below are for combustible and non-combustible installations and will allow for safe and proper
operation of your appliance.

In addition to the above clearances there must also be at least 16 inches (40.64cm) of aisle space in front of the unit.

1.3. PLUMBING

CONNECTIONS

The plumbing installation should be done by a licensed plumber and must comply with local and national codes.
The instructions for appliances connected to the water mains by detachable hose sets shall state that new hose
sets will be used and that the old hose sets should not be reused (if applicable).

1.3.1. WATER INLET CONNECTIONS
If your appliance is equipped with a faucet or a water fill option connections to a potable water supply will be
required. If a single water connection is required it is recommended that the appliance is connected to hot water
supply. This will greatly decrease the time and energy required for the appliance to reach operating temperature.
Prior to installation, a water treatment specialist should inspect the water supply. Water hardness should contain
no more then 2.0 grains/gallon. The pH level should be between 6.5 and 8.0. These conditions can be obtained
with the use of a properly maintained water softener. The incoming water pressure should be between 20 psi (138
kPa) to 60 psi (414 kPa). For higher water pressures, a high-pressure regulator must be installed to inlet plumbing
to avoid damage caused by water hammer. The maximum allowable incoming water temperature is 180°F
(82°C). Have your water tested and record the measured values below.

1.3.2. DRAIN

CONNECTIONS

Each tank has a drain that can be connected to a drainage system. Each tank also has an overflow line. The
overflow connection is after the drain valve to provide an unobstructed overflow path. The tank drain and
overflow line for each tank is connected together to form a common drain line.

When there are more than 2 appliances joined together the common drains can be connected together with a
manifold that has a 1-1/4” NPT outlet connection.

WARNING

DO NOT sit or stand on this appliance. The appliance’s front panel, tank,
splash back, tank cover, workshelf, drain board is not a step. Serious
injury could result from slipping, falling or contact with hot liquids.

Unit

Combustible Construction

Inches (centimeters)

Non-Combustible Construction

Inches (centimeters)

Back

6.0" (15.24cm)

0.0" (0.0cm)

Sides

6.0" (15.24cm)

0.0" (0.0cm)

Floor

6.0" (15.24cm)

6.0" (15.24cm)