TH-CRTE COUNTER TOP RETHERMAILZER

TROUBLESHOOTING

L20-417, rev. 0 (07/13)

12

Problem

Probable Cause

Corrective Action

No power to appliance

Check main building power supply

Circuit breaker tripped

Reset power supply Circuit Breaker

I/O switch in the O (off) position

Press the power switch to the start position and 
release

Power cord disconnected

Check power cord connection

High temperature limit tripped

Allow the appliance to cool to room temperature
and the high limit switch will auto‐reset

Low water level

Fill appliance with water to LEVEL FILL line (s)

Circuit breaker tripped

Reset power supply Circuit Breaker

High temperature limit tripped

Allow the appliance to cool to room temperature
and the high limit switch will auto‐reset

Low water level

Fill appliance with water to LEVEL FILL line (s)

Control does not 

activate

Appliance stops 

heating

4.4. TROUBLESHOOTING

CHART














4.5. ELECTRICAL

SCHEMATIC