OPERATION
Initial startup:
After satisfying the installation requirements, the cream dispenser is ready to start. The unit will start when the power cord is
connected to a live electrical receptacle. If the compressor is not running when the unit is initially plugged in, check to make sure
that the Temperature Control is not set to the ‘off’ position. Allow the unit to run a minimum of two hours before loading it with
product.

Preparation For Use:
Once the unit has achieved proper operating temperature, observe the procedures noted in the label on the door liner for loading
cream into the cream dispenser. When removing an empty Cream Container, be sure to release (swivel) or remove the Valve
Assembly before pulling the Dispensing Tube out of the valve (see Valve Assembly section below). The end of the tube may need
to be cleaned daily with a clean cloth to prevent buildup which could affect the dispensing of product.

Temperature Control:
The Temperature Control is factory set at the midpoint position, which will maintain an average product temperature of around 36 -
38 Deg F.

Defrost:
The Silver King cream dispenser is a manual defrost unit. The unit should be defrosted whenever the walls accumulate a frost bank
that is .5 inch (1.27cm) thick. To defrost the unit, either turn the Temperature Control knob to the ‘off’ position or disconnect the
power cord from the electrical receptacle, and open the door. After the frost has melted or come loose from the cabinet walls, wipe
out the cabinet interior. Do not attempt to scrape or chisel off the frost as you could do irreparable damage to the unit.

MAINTENANCE
Preventative maintenance is minimal although these few steps are very important to continued operation and maximizing the life of
the appliance.

Cabinet Surfaces:
The cabinet interior and exterior are stainless steel and should be cleaned periodically with a solution of warm water and a mild
soap, rinsed and wiped dry with a clean soft cloth. A stainless steel cleaner can also be used. Should a surface become stained or
discolored, do not attempt to clean with an abrasive cleaner or scouring pad. Use a soft cleaner and rub with the grain of the metal
to avoid scratching the surface. Do not use chlorinated cleaners.

Valve Assembly:
To dis-assemble the valve for cleaning, with the door open, pull the release latch on the top of the Valve Assembly. The Valve
Assembly will then swivel forward and then slide up and out at an angle. Clean the Valve Assembly with a solution of mild soap and
warm water or in a dishwasher. Rinse, dry and re-assemble. The Valve Body must be cleaned in place as it is not readily
removable.