Silver King SKCTMDI User Manual

Page 3

Advertising
background image

2


OPERATION

Initial Start Up

After satisfying the installation requirements, the counter-top drop-in display merchandiser is ready to start. The unit will start when

the power cord is connected to the required power source. If the compressor does not start when the unit is initially plugged in,
check to make sure that the Temperature Control is not in the ‘off’ position. Allow the unit to run for two hours before loading it with

product. When loading the unit with product do not load above the ‘product load line’ indicated on the liner.

Temperature Control

The Temperature Control is located on the front of the lower condensing unit. Turn the Temperature Control stem clockwise to

obtain colder cabinet temperatures and vice versa. Allow the unit a minimum of two hours to respond to a control setting

adjustment.

Defrost

The Silver King counter-top drop-in display merchandiser is a manual defrost unit. The unit should be defrosted whenever the walls

accumulate a frost layer that is 1/4 inch thick. To defrost the unit, either turn the Temperature Control stem to the ‘off’ position (fully
counterclockwise) or disconnect the Power Cord from the electrical receptacle, and remove the Lid Assembly. After the frost has

melted or come loose from the walls, wipe out the cabinet interior. Do not attempt to scrape or chisel off the frost as you could do

irreparable damage to the unit.

MAINTENANCE

Preventative maintenance is minimal although these few steps are very important to continued trouble free operation and

maximizing the life of your appliance.

Cabinet Surfaces

The cabinet interior and exterior surfaces should be cleaned periodically with a solution of warm water and mild soap and wiped dry

with a soft cloth. A good stainless steel cleaner can also be used. Should a surface become discolored, do not attempt to clean
with an abrasive cleanser or scouring pad. Use a soft cleanser and rub with the grain of the metal to avoid scratching the surface.

Do not use chlorinated cleaners on the stainless steel.

Condenser

Periodically, accumulated dust must be removed from the condenser. First, disconnect the unit from the power supply. To clear the

dust, blow air though the condenser fins or remove the back panel and brush the dust from the backside of the condenser.

MODEL

SERIAL NO.

DATE INSTALLED

Advertising