OPERATION
Initial Start up:

After satisfying the installation requirements, the Lettuce Dispenser is ready to operate. The unit will start when the Power Cord is
connected to a live electrical receptacle. If the Compressor and Condenser Fan are not running when the unit is initially plugged in,
check to make sure that the Temperature Control is not set to the ‘off’ position. Allow the unit to run a minimum of one (1) hour
before loading it with product.

Temperature Control:
The Temperature Control, located on the upper left side of the cabinet, comes set at the midpoint position, #4, which will maintain an
average cabinet temperature of about 38 Deg F. To obtain cooler temperatures turn the Temperature Control stem clockwise with a
slotted screwdriver and vise versa. Allow the unit a minimum of six (6) hours to respond to a control setting adjustment if the
product is in the cabinet.

Temperature Indicator:
The Temperature Indicator mounted on the upper face of the cabinet is factory set to indicate the temperature of the product within
two (2) degrees. Should the Temperature Indicator read inaccurately there are instructions for re calibrating it located on the Door
Liner.

Defrost:
The SK2SB Lettuce Dispenser is a manual defrost unit. The unit should be defrosted whenever the walls accumulate a frost/ice
bank the is 1/2 inch thick. To defrost the unit, first remove the Lettuce Bin from the unit then either turn the Temperature Control to
the ‘off’ position or disconnect the Power Cord from the electrical receptacle, and open the Door. After the frost/ice has melted or
come loose from the cabinet walls, wipe out the cabinet interior with a dry cloth or sponge. Do not attempt to scrape or chisel off the
frost/ice as you could do irreparable damage to the cabinet.

MAINTENANCE
Preventative maintenance is minimal although these few steps are very important to continued operation and maximizing the life of
the appliance.

Cabinet Surfaces:
The interior and exterior surfaces are stainless steel and should be cleaned periodically with a solution of warm water and a mild
soap and wiped dry with a clean soft cloth. Should a surface become stained or discolored, do not attempt to clean with an abrasive
cleaner or scouring pad. Use a soft cleaner and rub with the grain of the metal to avoid scratching the surface.

Condenser:
Periodically, dust accumulated on the Condenser should be removed. First, disconnect the unit from the power supply. Remove
the top panel to expose the Condenser. Remove the accumulated dust by vacuuming or blowing air through the coil. This
procedure will save on Compressor running time (electrical costs) and also extend the life of the Compressor.

Door Gasket:
To extend the life of the door gaskets, clean them regularly by wiping them with a solution of warm mild soapy water and rinse with