Voltage selection, Ventilation – TurboChef Technologies Fire Oven User Manual

Page 11

Advertising
background image

SPECIFICATIONS

AND

INSTALLATION

3

Installation Near Open Heat Source

When placing a TurboChef oven near an open
heat source (Figure 2), strictly adhere to the
following:

- If the oven is being placed near a grill or stove,

a divider must exist between the oven and the

open heat source, with a minimum of 6” (152

mm) between the oven and the divider.

- If the oven is being placed near a fryer, a

divider must exist between the oven and fryer,

with a minimum of 12” (305 mm) between

the oven and the divider.

- The height of the divider must be greater than

or equal to the height of the oven (22.7” or

576.6

mm).

- Verify the oven location has a minimum 2”

(51 mm) clearance on top and a minimum 2”

(51 mm) clearance on each side.

Voltage Selection

For North America oven models, the oven will
detect 208 or 240 incoming voltage.

Ventilation

The TurboChef Fire oven has been approved by
Underwriter’s Laboratory LLC for ventless
operation (UL® KNLZ listing) for all food items
except for foods classified as “fatty raw proteins.”
Such foods include bone-in, skin-on chicken, raw
hamburger meat, raw bacon, raw sausage, steaks,
etc. If cooking these types of foods, consult local
HVAC codes and authorities to ensure compliance
with ventilation requirements.

To ensure continued compliance with all health,
building, and fire codes, you are required to main-
tain clean and sanitary conditions around your
oven at all times.

NOTE: In no event shall the manufacturer assume
any liability for damages or injuries resulting from
installations which are not in compliance with the
instructions and codes previously listed. Failure to
comply with these instructions could result in the
issuance of a temporary cease and desist order from
the local health department until the environment
concerns are addressed.

Figure 2: Installation Near Open Heat Source

Grill

Partition

22.7” (576.6 mm)
Above Counter Top

6”

(152 mm)
Minimum

12”

(305 mm)
Minimum

Deep Fryer

Counter Top / Table

Partition

22.7” (576.6 mm)
Above Counter Top