INSTALLATION & MAINTENANCE INSTRUCTIONS

AREA LIGHT ASA SERIES

American Electric Lighting a division of Acuity Lighting Group, Inc. Conyers, GA

DRAWING NO. A67853 REV -

(FRONT)

©2005 ACUITY LIGHTING GROUP, INC.

PART NUMBER 057-70-67853

1.Loosen the four captive screws or optional latches in the door assembly

allowing it to open and hang from the hinge pins. The door assembly can be

removed by rotating it back and sliding the door to the right, off the hinge pins.

The optional hingekeeper will have to be removed if installed. See Fig. 1.
2.Loosen the screws securing the reflector to the housing. Unplug

the disconnect circuit and remove the reflector/socket assembly.

The electrical components will now be exposed
3. TO POLE MOUNT- Remove top cap from the pole, if in place.

Position mounting plate inside the pole or tenon adaptor. Insert

the two threaded rods through the drilled hole in pole and turn

rods to thread securely into mounting plate.

FOR WALL MOUNT- Place mounting plate on mounting surface.

Mark top, middle and bottom holes of the plate (see diagram) .

Remove mounting plate and drill 5/8" hole at marked locations

(minimum of 3/4" to accept fixture mounting rods). Secure

mounting plate to mounting surface (fasteners not provided) using

second and fourth holes. Insert the two threaded fixture mounting

rods into mounting plate and turn to secure.
4. Slide gasket over rods and position against pole. Slide arm

over rods and place second gasket at end of arm. Position housing

at end of arm and align holes with threaded rods. Insert into holes.

Install split washer and nut to each rod and tighten securely. Be

sure fixture is mounted straight and gaskets are in place. Feed wires

from electrical components through arm and make wire connections

in outlet box or pole. Replace pole top cap or coverplate. Reinstall

the reflector assembly. Be sure to securely reconnect the plug at this time.
5. To install lamp (not included) , check to make sure the lamp is

the corrrect source and wattage. Screw the lamp securely into the

socket, back it out one or two turns , then screw the lamp back in,

making sure the lamp is secure. This procedure properly seats the

lamp into the socket.
6. Reinstall door, if removed, and close. Secure with the four closing screws or latches.

Assembly, Mounting and Wiring

WARNING

DISCONNECT POWER BEFORE RELAMPING OR WIRING THE FIXTURE.

READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION.

!

CAUTION

TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL APPLICABLE NATIONAL

AND LOCAL ELECTRICAL/BUILDING CODES. FOR CODE INTERPRETATION, CONSULT LOCAL CODE AUTHORITY.

!

WARNING

RISK OF FIRE. PRODUCT FOR OUTDOOR INSTALLATION AND USE ONLY.

!

THREADED RODS

ARM

OPTIONAL LATCHES

NUTS AND WASHERS

REFLECTOR ASSY

REFLECTOR SCREW

GASKETS

Slide Bezel this

way to remove

Fig. 1

WIRES

Advertising