American Electric Lighting 30 new User Manual

Standard mast mount, Durastar series 30, Warning

Advertising
background image

INSTALLATION INSTRUCTIONS

DURASTAR 30 SERIES LUMINAIRE

American Electric Lighting a division of Acuity Lighting Group, Inc. Conyers, GA

DRAWING NO. B63632 REV D

(FRONT)

©2003 ACUITY LIGHTING GROUP, INC.

PART NUMBER 057-70-63632

WARNING

!

DISCONNECT POWER DURING INSTALLATION AND BEFORE SERVICING

TO AVOID THE RISK OF SEVERE OR FATAL ELECTRICAL SHOCK

CAUTION

DO NOT OVER TORQUE

!

Figure 3

Figure 2

Figure 1

Install lower mast mount cover to upper mast mount

housing. Tighten two bolts to 5 ft-lbs. torque.

"Mast Mount" installation is now complete.

MOUNTING

POSITION

LOCKED

POSITION

REMOVAL

POSITION

STANDARD MAST MOUNT

Wild Life Shield Knockouts

Stair Case Ribs

Indicator Arrow

Voltage Setting

M

UL

TI-

480

V--

347V

--

277V--

240V--

230V

--

220

V--

20

8V

--

12

0V

--

Locked Position

Mounting Position

Upper Mast Mount

Lower Mast Mount

Locking Spring

Power Receptacle

Mast Arm

Level Ribs

Fitter Clamp Bolts

Fitter Clamp

Durastar Luminaire Installation/Removal:

Installation:

1. Grasp the luminaire as shown in Mounting Position Detail.

2. Align locking spring as shown in bottom view

of mounting position detail.

3. Rotate the luminaire 20° clockwise, with forward

pressure to compress O-ring. Locking spring should

snap into slot as shown in locked position detail.

Removal:

1. Push locking spring back into removal position.

2. Rotate the luminaire 20° counter clockwise .

3. Pull the luminaire from Mast Mount.

Mast Mount Installation:

For best results the installer should be positioned directly under

and facing the end of the mast arm. If 2" mast arm is used,

remove wild life shield knockouts with pliers and reverse clamp.

Loosen fitter clamp bolts 1/2" for 1 1/4 mast arm or 1 1/4"

for 2" mast arm. Slide mast mount upper onto mast arm and level

on stair case ribs. Level using cross hair ribs if needed.

Torque bolts to 10 ft.-lbs.

Wiring:

Feed the supply wires through the mast arm. Dress them so

they do not interfere with any components and connect them

to the proper terminals on the receptacle. Verify that

the supply voltage is correct as noted on the nameplate.

Refer to the wiring diagram and the data on the nameplate

for connection information and ratings. Rotate the

receptacle to match your supply voltage marking with the

arrow head located in the upper mast mount and press fit

it in place. (Note: Can be placed in lower mast mount if desired)

POWER PLUGS of single voltage luminaires have

been set to match factory wired voltage. POWER

PLUGS of DUAL/MULTI voltage luminaires have been

set to the "MULTI" position for field changes

of voltage. Refer to MULTI-VOLT label, 3-wire

operation label and wiring diagram on inside

wall of luminaire.

Securing Mast Mount Lower:

Locking Spring

CAUTION

DO NOT OVER TORQUE

!

CAUTION

LOCKING SPRING MUST BE

LOCKED AS SHOWN IN FIG. 2

!

TM

DURASTAR SERIES 30

Ignitor

Advertising