INSTALLATION & MAINTENANCE INSTRUCTIONS

115 & 315 SERIES HORIZONTAL LUMINAIRES

(FOUR BOLT LOCKING AND LEVELING)

American Electric Lighting a division of Acuity Lighting Group, Inc. Conyers, GA

DRAWING NO. B61169 REV D

(FRONT)

©2003 ACUITY LIGHTING GROUP, INC.

PART NUMBER 058-71-61169

WARNING

DISCONNECT POWER BEFORE RELAMPING OR WIRING THE FIXTURE.

READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION

TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL APPLICABLE NATIONAL

AND LOCAL ELECTRICAL/BUILDING CODES. FOR CODE INTERPRETATION, CONSULT LOCAL CODE AUTHORITY

RISK OF FIRE. PRODUCT FOR OUTDOOR INSTALLATION AND USE ONLY.

WARNING

CAUTION

!

!

!

WARNING

ENSURE THAT ALL POWER IS

DISCONNECTED PRIOR TO WIRING

!

REMOVE LOWER HOUSING:

FIXTURES WITH ONE-PIECE LOWER:

Lift lower housing hinge pins out of the hinges in the upper housing.

Slide lower housing off of hinge bar.

FIXTURES WITH POWER-PAD:

Unfasten the power-pad latch screw. NOTE: The power-pad is

HEAVY, and it should not be allowed to drop free and swing.

Disconnect the two sets of electrical connectors, and then unhook

the power-pad from the hinge bar and remove it.

MOUNTING / LEVELING:

FOUR BOLT FITTER:

1-1/4" MAST ARM - Loosen the four fitter clamp bolts until the fitter

will slip over the mast arm.

2" MAST ARM - Loosen the four fitter clamp bolts. Remove the

plastic bird shield and break out the pierced section to allow it to fit

into the 2" mast arm. Replace the bird shield. Slide the luminaire

onto the mast arm to the stop and tighten the fitter clamp bolts tight.

LEVELING:

Place a level on the area provided on top of the luminaire. If the

luminaire is not level from side to side, twist the luminaire on the

mast arm until it is level

FOUR BOLT FITTER:

Tighten all four bolts. If the FRONT END IS LOW, loosen the two

front fitter bolts and tighten the two rear ones. Repeat this procedure

until the luminaire is level.

If the FRONT END IS HIGH, loosen the two rear fitter bolts and

tighten the two front ones. Repeat this procedure until the luminaire

is level.

When the luminaire is level, tighten the fitter clamp bolts with a

wrench to 10 ft.lbs for 2" MAST ARMS or 1/16" deflection,

or 15 ft.lbs for 1-1/4" MAST ARMS or 1/16" deflection.

CAUTION

OVER-TORQUING OF FITTER CLAMP BOLTS CAN

CREATE CRACKS IN THE HOUSING CAUSING

THE FIXTURE TO FALL TO THE GROUND.

!

INPUT VOLTAGE:

If the voltage available is different from that shown on the terminal block,

consult the wiring diagram for directions.

WIRING:

Feed the supply wires through the mast arm, dress them so they do not

interfere with any components, and connect them to the proper terminals

on the terminal block. Verify that supply voltage is correct as noted on

the terminal block label. Refer to the wiring diagram and the data on the

ballast for connection information and ratings.

INSTALLING LOWER HOUSING:

FIXTURES WITH ONE-PIECE LOWER:

Insert lower housing hinge pins into the hinge cradles of the upper

housing. Swing the lower housing into position and press firmly upward

until latch snaps into position. NOTE: IT IS NEVER NECESSARY OR

ADVISABLE TO SLAM THE HOUSING CLOSED!

FIXTURES WITH POWER-PAD:

To install the ballastry power-pad, engage the hinge hook with the hinge

bar on the upper housing. Connect the two sets of electrical connectors

firmly together. (These connectors are "polarized" so they will only fit

together one way.) Swing the power-pad closed. Fasten the latch screw

until it is firmly seated, but DO NOT OVERTIGHTEN IT.

MOUNTING / LEVELING (cont.):

CSA SPECIAL REQUIREMENTS:

Slide the weather guard onto the mast arm first. Carefully fold back the

insulating barrier along the score line to expose the fitter bolts. Install

the fixture as directed in the standard mounting instructions. Once

fixture has been installed, slide the weather guard along the mast arm

until it is firmly seated against the rear of the luminaire housing. Apply

RTV sealant between the weather guard and the housing creating a

water-tight seal. Once wiring has been completed, fold the insulating

barrier back into place.