American Electric Lighting 882 User Manual

Warning, Warning caution, C of fixture

Advertising
background image

INSTALLATION INSTRUCTIONS

882 SERIES SIDELITE LUMINAIRE

American Electric Lighting a division of Acuity Lighting Group, Inc. Conyers, GA

DRAWING NO. B23848 REV C

(FRONT)

©2004 ACUITY LIGHTING GROUP, INC.

PART NUMBER 057-70-23848

WARNING

DISCONNECT POWER BEFORE RELAMPING OR WIRING THE FIXTURE.

REAR HOUSING MUST BE GROUNDED TO REDUCE POTENTIAL OF ELECTRICAL SHOCK

READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION

TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL APPLICABLE NATIONAL

AND LOCAL ELECTRICAL/BUILDING CODES. FOR CODE INTERPRETATION, CONSULT LOCAL CODE AUTHORITY

RISK OF FIRE. PRODUCT FOR OUTDOOR INSTALLATION AND USE ONLY.

WARNING

CAUTION

!

!

!

LOOSEN (2) CAPTIVE SCREW "A" UNTIL FREE. REMOVE FRONT HOUSING ASSEMBLY.

LOOSEN (2) REFLECTOR SCREW AND REMOVE REFLECTOR AND BARRIER.

AFTER FIXTURE INSTALLATION, REPLACE BARRIER AND REFLECTOR.

1. DRILL OR KOCKOUT (3) 5/16"HOLES IN BOSSES PROVIDED

ON BACK OF REAR HOUSING.

2. REMOVE THREADED PLUG FROM WIRING ACCESS HOLE.

3. SECURE FIXTURE TO WALL. USE 1/4" DIA. SCREWS MIN.

REFER TO LAYOUT BELOW FOR HOLES LOCATION.

4. CONNECT SUPPLY LEADS TO FIXTURE LEADS.

GROUND FIXTURE WITH GROUND WIRE PROVIDED.

KEEP WIRE CONNECTIONS INSIDE JUNCTION BOX.

1. DRILL OR KNOCKOUT (3) 5/16" HOLES IN BOSSES

PROVIDED ON BACK OF REAR HOUSING.

2. SECURE FIXTURE TO WALL. USE 1/4" DIA.

SCREWS MIN. REFER TO LAYOUT BELOW FOR HOLES

LOCATION.

3. REMOVE PLUG(S) AND THREAD CONDUIT TO ONE OR

BOTH SIDES OF FIXTURE.

4. CONNECT SUPPLY LEADS TO FIXTURE LEADS. GROUND FIXTURE

WITH GROUND WIRE PROVIDED. KEEP WIRE CONNECTIONS

INSIDE REAR HOUSING.

FIG.1

A. FOR DIRECT MOUNTING TO EXISTING FLUSH JUNCTION BOX:

B. FOR DIRECT MOUNT/WITHOUT JUNCTION BOX:

5. CAULK AROUND JUNCTION BOX WITH A SILICON

TYPE CAULKING TO PROVIDE A WATER-TIGHT SEAL.

PHOTOCONTROL

(OPTIONAL)

REAR HOUSING

FRONT HOUSING

ASSEMBLY

SCREW "A"

MOUNTING HOLES

MOUNTING HOLE

C OF FIXTURE

ACCESS HOLES

HOLES LAYOUT

2

3/

4

2

3/

4

6

6

7/

8

L

Advertising