3 technical data, 3technical data – Beijer Electronics EXTER T40/T40m EN User Manual

Page 13

Advertising
background image

Technical Data

Beijer Electronics, MAEN812C

13

3

Technical Data

Parameter

EXTER T40

EXTER

T40m

Front panel,
W x H x D

155.8 x 119 x 6 mm

Mounting
depth

57 mm (157 mm including clearance)

Front panel
seal

IP 66

Rear panel
seal

IP 20

Touch
screen
material

Touch screen: Polyester on glass, 1 million finger touch operations.
Overlay: Autotex F157/F207 *.

Reverse side
material

Powder-coated aluminum

Weight

0.6 kg

Serial port
RS422/
RS485

25-pin D-sub contact, chassis-mounted female with standard locking screws
4-40 UNC.

Serial port
RS232C

9-pin D-sub contact, male with standard locking screws 4-40 UNC.

Ethernet

Shielded RJ 45

USB

Host type A (USB 1.1), max output current 500 mA

Flash
memory for
application

12 MB (incl. fonts)

Real time
clock

±20 PPM + error because of ambient temperature and supply voltage. Total
maximum error: 1 min/month at 25

°

C

Temperature coefficient: 0.004 ppm/

°

C

2

Real time
clock
battery

CR2450 (UL and cUL: Sanyo or Panasonic)
Minimum lifetime: 3 years

Power
consumption
at rated
voltage

Normal: 0.15 A
Maximum: 0.35 A

Display

TFT-LCD.
320 x 240 pixels, 64K colors.
LED backlight lifetime at the
ambient temperature of
+25

°

C: >10,000 h.

TFT-LCD.
320 x 240 pixels, 16 greyscales.
LED backlight lifetime at the
ambient temperature of
+25

°

C: >10,000 h.

Active area
of display,
W x H

70.1 x 52.6 mm

Fuse

Internal DC fuse, 2.0 AT, 5 x 20 mm

Power
supply

+24V DC (20 - 30V DC). Power supply connector.
CE: The power supply must conform with the requirements according to IEC
60950 and IEC 61558-2-4.
UL and cUL: The power supply must conform with the requirements for class
II power supplies.

Ambient
temperature

Vertical installation: 0

°

to +50

°

C

Horizontal installation: 0

°

to +40

°

C

Storage
temperature

-20

°

to +70

°

C

Advertising