3 technical data, 3technical data – Beijer Electronics EXTER K100 EN User Manual

Page 13

Advertising
background image

Technical Data

Beijer Electronics, MAEN773D

13

3

Technical Data

Parameter

EXTER K100

Front panel, W x H x D 382 x 252 x 6 mm
Mounting depth

58 mm (158 mm including clearance)

Front panel seal

IP 66

Rear panel seal

IP 20

Keyboard material

Membrane switch keyboard with metal domes. Overlay film
of Autotex F157 * with print on reverse side. 1 million
operations.

Reverse side material

Powder-coated aluminum

Weight

2.5 kg

Serial port RS422/
RS485

25-pin D-sub contact, chassis-mounted female with
standard locking screws 4-40 UNC.

Serial port RS232C

9-pin D-sub contact, male with standard locking screws 4-40
UNC.

Ethernet

Shielded RJ 45

USB

Host type A (USB 1.1), max output current 500mA
Device type B (USB 1.1)

CF-slot

Compact flash, type I and II

Flash memory for
application

12 MB (incl. fonts)

Real time clock

±20 PPM + error because of ambient temperature and supply
voltage. Total maximum error: 1 min/month at 25

°

C

Temperature coefficient: 0.004 ppm/

°

C

2

Real time clock
battery

CR2450 (UL and cUL: Sanyo or Panasonic)
Minimum lifetime: 3 years

Power consumption at
rated voltage

Normal: 0.5 A
Maximum: 1.0 A

Display

TFT-LCD. 800 x 600 pixels, 64K color.
CCFL backlight lifetime at the ambient temperature of
+25

°

C: >50,000 h.

Active area of display,
W x H

211.2 x 158.4 mm

Fuse

Internal DC fuse, 3.15 AT, 5 x 20 mm

Power supply

+24V DC (20 - 30V DC). Power supply connector.
CE: The power supply must conform with the requirements
according to IEC 60950 and IEC 61558-2-4.
UL and cUL: The power supply must conform with the
requirements for class II power supplies.

Ambient temperature

Vertical installation: 0

°

to +50

°

C

Horizontal installation: 0

°

to +40

°

C

Storage temperature

-20

°

to +70

°

C

Relative humidity

5 - 85 % non-condensed

CE approvals

Noise tested according to EN61000-6-4 emission and
EN61000-6-2 immunity.

UL, cUL approvals
(when procuct or
packing is marked)

UL 1604 Class I, Div 2 / UL 508 / UL 50 4x indoor use only

DNV

Yes

NEMA

4x indoor use only

* See section

Chemical Resistance

for more information.