1 self-test of the display, 2 calibrating the touch screen – Beijer Electronics iX Panel T150 EN User Manual

Page 25

Advertising
background image

Hardware Replacement

5. Remove the mounting plate (12 torx screws). Gently lift the mounting plate

with the display and power card.

12 x torx screws

6. Flip the mounting plate and unscrew the 4 torx screws, located on front or

side.

4 x torx screws

7. Re-assemble the panel in reverse order.

8.4.1

Self-test of the Display

To perform a self-test of the display, follow the steps below:
1. Start the operator panel in a self-test mode (see table in the

Mode Switches

section).

2. Go to the display test. Verify that the display works.
3. If the screen does not work, try fault tracing, see the

Fault Tracing

section.

8.4.2

Calibrating the Touch Screen

Note:
A USB keyboard and a USB mouse must be connected to the operator panel.

Follow the steps below to calibrate the touch screen:
1. Set the MODE switches to the correct positions in order to enter the Service

Menu mode (see table in the

Mode Switches

section).

2. Switch on the power and follow the instructions.
3. Power off the operating panel.

Beijer Electronics, MAEN008

25

Advertising