2 1

ULI Hourly Fire
Resistance Ratings for
PMR – Steel Deck

Note: Always refer to the actual listing for complete details, including
maximum thickness of insulation allowed. For details, call Dow at
1-866-583-BLUE (2583).

Assembly #

P-225, P-226, P-235
(New PMR)

P-404
(New PMR)

P-801, P-805
(Retrofit PMR)

P-803
(Retrofit PMR)

P-811
(New PMR)

P-813
(New PMR)

P-908

Rating (hrs)

1, 1-1/2

1-1/2

1, 1-1/2, 2

1, 1-1/2

1, 1-1/2, 2, 3

1, 1-1/2

2

Description

Steel deck
1/2" or 5/8" (13 mm or 16 mm)
Type X gypsum (varies)
Bar joists
Suspended ceiling

Steel deck
1" (25 mm) mineral or fiberboard
Bar joists
Plaster ceiling

Steel deck
Mineral or fiberboards
Spray fiber fireproofing
Beam construction

Steel deck
Mineral or fiberboards
Spray fiber fireproofing
Bar joists

Steel deck
5/8" (16 mm) Type X gypsum
Spray fiber fireproofing
Beam construction
Suspended ceiling (optional)

Steel deck
5/8" (16 mm) Type X gypsum
Spray fiber fireproofing
Bar joists

Steel deck
3-5/6" (97 mm) vermiculite concrete
Beam construction