6 - TROUBLESHOOTING

Some incidents may arise when you are using your dryer. Here are the points you should check:

7 - INTERVENTIONS

Any work on your appliance must be performed by a Brand-approved qualified professional. When you call,
mention your appliance’s full reference (model, type, serial number). These details are shown on the manufac-
turer’s information plate

(Fig. 1.1).

Fault:

Check whether:

The dryer does not start:

- the plug is in the socket.
- the door is properly closed.
- the condenser is correctly locked in place.
- the “Start” key was pressed (if the appliance was

not in pause).

The drying times are too long:

- the filter in the drum is clogged with fluff.
- the laundry has been spun enough beforehand

(500rpm minimum, but spinning at 850rpm provides
better drying times).

- the room temperature is not too high, particularly if

the room is small: if necessary, open the door or
window.

- the condenser is not clogged.
- the air inlets and outlets are unobstructed enough to

ensure correct air circulation.

- the drying program selected matches the type of

items in the drum.

The laundry is too damp:

- the filter in the drum is clogged with fluff.
- the type of drying has been selected correctly:

switch to the next programme.

- the condenser is not blocked by fluff.

The laundry is too dry, too creased:

- the drying program selected matches the type of

items in the drum.

The items are unevenly dried:

- the types of textiles in the load are too different (e.g.

sheets together with jeans).

- the laundry has been laid correctly ‘unfolded’ in the

dryer.

- the drum is not overloaded.

The synthetic items are loaded with
static electricity:

- the laundry has been dried too much.
- you have used softener during washing. By using

this product, you can reduce most of the problems
with static electricity.

The “Tank Full” indicator light is lit:

- the condensate container is full: once you have emp-

tied it, re-insert it correctly, pushing it completely
into its housing.

The “Tank Full” indicator light illumina-
tes although the tank is empty:

- the container has been properly inserted: push it in

completely.

- the condenser is tightly locked on the two sides.

NOTES