AL7020S, AL7024S Designer’s Guide

Doc. No. DG_7024E

Altec Electronic AG

Seite 10 / 32


Table 3-2. Signal Descriptions



Label


I/O Type


Signal Name/Description

VCC PWR

+5 VDC. A standard 5V +/- 5% - 1.5A power supply is strictly required to
supply this module (5V Versions). Average current is 270mA
(350mA @ PCL5). See also chapter 5.1.2

+3.-3 VDC. A standard 3.3V +/- 5% - 1A power supply is strictly required to
supply this module (3V Versions). Average current is 270mA
(350mA @ PCL5). See also chapter 5.1.3

GND GND

Digital Ground Connect to Digital Ground on the interface circuit.

~RESET IC

Modem Reset (ON/OFF). To be pulled to ground by external transistor for
reset. (on module pull-up resistor of 200K). The GSM Modem has already an
internal power-up reset circuit. Needs special timing for RESET and ON/OFF
function (see chapter 3.8)

AGND GND

Analog Ground. if a microphone or headset is used, use this as a ground. If
these are never used, it can be connected to DGND.





OPTIONAL SIM CARD READER INTERFACE

Label

I/O Type Signal Name/Description

SIMCLK O


SIM Clock. Provided from module.

SIMRST O


SIM Reset. Provided from Module to reset the SIM Card.

SIMDATA I/O


SIM Data line. Digital, bi-directional data line to exchange data between
module and SIM card.

SIMVCC PWR


SIM Power Supply
. 3VDC Power Supply provided from module to power
the SIM Card. Only 3V SIM Cards are supported.