Pathway #1002 eDIN Opto-Splitter User Manual

Anual, Edin opto-splitter

Advertising
background image

The POWER LED on the face of your
eDIN Opto-Splitter will illuminate when
power is connected to the unit. There is
no on/off switch.

The DATA IN LED will illuminate and
flicker rapidly to indicate that DMX data
is being received.

Each DMX output has an associated
LED to show that the output is opera-
tional and DMX data is being transmit-
ted.

Indicators

1002

eDIN 4-Way Opto Splitter

1001

eDIN 15W power supply

1102-30 Additional 12” (30cm) DIN mounting rail

Required
Power Supply:

9-30V AC/DC, 5W

Connections: Two-part screw terminals

Isolation:

2500V Opto-isolation

Protection:

Up to 250VAC/DC on all
port pins

Protocols:

DMX512 , DMX512-A, or any
EIA422 /485 based protocol

Size:

4.64 x 4.5 x 1.5”
(118 x 113 x 38 mm)

Unit Weight: 0.5 lbs. (0.25 kg)

eDIN Model Descriptions

Specifications

eDIN modules are designed to work
on voltages from 9-30 volts AC or DC
only. DIN rail power supplies are
readily available from Pathway and
most electrical suppliers.

Each eDIN opto consumes 5 watts of
power.

CAUTION!

Subject to change without notice

103 Inglewood Plaza 1439 17Avenue SE Calgary AB, Canada T2G 1J9 • +1 403 243-8110 Fax +1 403 287-1281

Printed in Canada

Typical Application

HOUSE

DIMMERS

STAGE

DIMMERS

CONTROL CONSOLE

eDIN Opto

eDIN Opto

RELAY

CABINET

COLOR

SCROLLERS

MOVING

LIGHTS

MOVING

LIGHTS

THRU

IN

IN

DMX Termination

If only one eDIN Opto-Splitter is used,
and nothing is connected to the DMX
THRU connector, the termination switch
must be set in the ON position to
terminate the incoming DMX signal from
the console. If several eDIN optos are
connected together using the DMX
THRU connector on each unit, only the
last eDIN opto in the chain is terminated,
all the others are not terminated (switch
in the OFF position).

DMX receiving devices such as dimmers
or scrollers are generally provided with a
termination switch, termination jumper or
other means of connecting the required
termination resistance across the DMX
line. Always make sure that the last
receiving device connected to any output
line is properly terminated.

To ensure trouble free operation,
DMX512 standards require that DMX
devices be installed in a daisy chain,
with no tees, wyes or stars in the DMX
wiring. However, site conditions may
make star wiring desirable or even
mandatory. A Pathway eDIN Opto-
Splitter permits star wiring by making
each branch of the star function
electrically as its own entity, unaffected
by the other branches of the star.
Additionally, opto-isolation circuitry
prevents ground loops or accidental
damage to control consoles from fault
voltages on DMX lines.

Operational Philosophy

• All wiring must be in a continuous run,

daisy-chained, no “Tees” are permitted

• “Stars” are permitted only in

conjunction with a repeater

• Cable shield may be earth-grounded

at one end only: at the control console
output and the eDIN opto outputs

• Maximum length of one cable segment

is 1,800 ft. (550m).

• Receiving devices have male

connectors, transmitters have female

• The last DMX device on the line must

be terminated with a termination
switch or resistor with a value of 100 to
120 ohms

between pins 2 and 3.

• 5 pin XLR type DMX connectors are

standard:

Pin 1:

Common

Pin 2:

Data (-)

Pin 3:

Data (+)

Pin 4:

Optional Data (-)

Pin 5:

Optional Data (+)

• 3 pin XLR type connectors are a non-

standard alternative:

Pin 1:

Common

Pin 2:

Data (-)

Pin 3:

Data (+)

• Wire must be Belden 9842 (120Ω),

9829 (100

Ω), ISO/IEC 11801 (Cat5)

or equivalent

• A maximum of 32 DMX receiving

devices can be present on a single
DMX line

DMX Basics

DMX512-A Compliance

This product complies with the DMX512-
A standard, under the non-compatible
connector (NCC) provision.

All ports are DMX512-A protected to
250V.

U

SER

S

M

ANUAL

eDIN Opto-Splitter

Model# 1002

An essential component of any
DMX512 distribution system, the
eDIN Opto-Splitter permits star
wiring installations while isolating
an d p ro t ect i n g co nn ect ed
equipment from harmful electrical
faults. Pathway eDIN optos
feature self-healing protection
devices on all ports to prevent
internal damage when severe
faults of up to 250V are
accidentally applied to the
connected DMX cabling.

Advertising