Dmx decoder user guide, Model description specifications, 48 channel decoder card 24 channel decoder card – Pathway DMX Decoder - # 8721/8741 User Manual

Page 4: Dip switch settings, Output voltage adjustment, Output configuration, Output connector assignment, Power supply

Advertising
background image

DMXDecoder User Guide

8721

DMX input, 24 analog outputs

8721AC

DMX input, 24 analog outputs with internal
100-240VAC power supply

8741

DMX input, 48 analog outputs

8600

19” rack mount bracket kit

Power Supply:

9-12VDC @ 250mA (adaptor included)

Weight:

24 channel: 1.3 kg (2.9 lbs)
48 channel: 1.5 kg (3.3 lbs)

Size:

24 channel: 8 x 1.75 x 6.5” (203 x 44 x 165
mm)
48 channel: 8 x 1.75 x 11” (203 x 44 x 279
mm)

Model Description

Specifications

STATUS QUO HOLD TIME

1

Disabled (2 Sec. Time Out)

OFF

Enabled ( 5 Min. Time Out)

ON

Maintains last dimmer levels for set time on loss of input data
signal

2

When enabled allows analog dimmer outputs to be brought to
full one at a time as selected by the rotary address switches.

PROTOCOL SELECT

3

AMX-192 OR D54

OFF

DMX-512

ON

This switch is active only on 48 channel models,

TEST AND CALIBRATE MODE

DIP Switch Settings

DMX TERMINATION

4

DMX Line Unterminated

OFF

DMX Line Terminated

ON

This switch connects a 100-ohm resistor across the DMX data
pair. The unit should be terminated if it is the last receiving
device on the DMX line.

JP4

DP

1

DP

2

DP

3

DP

4

DP

5

DP

6

JP1

JP2

JP3

JP6

JP5

12

3

123

12

3

P1

JP1

JP4

JP3

JP2

P1

48 Channel Decoder Card

24 Channel Decoder Card

OUTPUT VOLTAGE ADJUSTMENT

(ALL MODELS)

OUTPUT CONFIGURATION

(48 CHANNEL MODELS)

CAUTION – Disconnect power from the unit before making
any changes
For 10V systems, JP1 and JP2 are installed: remove them for
15V systems. For positive outputs, jumper pins 2 and 3 of JP4,
5 and 6 and install diode packs DP1-6 with the notch facing
down (left). For negative outputs, jumper pins 1 and 2 of JP4, 5
and 6, and install the diode packs with the notch facing up
(right).

Before powering up, check to make sure all jumpers are

installed correctly. Damage will result if the unit is powered up
with any of the jumpers in the wrong position.

Place the unit in test mode (S1-2 on) and set the address
switches to 000 or 001. Ensure that the decoder is connected to
dimmer no. 1 and connect a DC voltmeter between COM and
output terminal no. 1 on the circuit board. Adjust P1 to

achieve

the desired control voltage.

OUTPUT CONNECTOR ASSIGNMENT

(ALL MODELS)

If your decoder uses 25-pin D-type output connectors, you must
install JP1 on 24 channel units or JP3 on 48 channel units. This
will reassign the output control signals to confirm to the analog
pin assignment detail on page 3.

OUTPUT CONFIGURATION

(24 CHANNEL MODELS)

For 10V systems, JP2 is installed and JP3 and JP4 are
removed. For 15V systems, JP2 is removed and JP3, JP4 are
installed.

05/02