LCDM24 DEMULTIPLEXER Configuration

LED INDICATORS

CONNECTOR J1

V+

12VDC @ 250mA

COM

Power Supply and Signal Common

COM

Power Supply and Signal Common

CD-

Signal Input USITT DMX512/AMX192

Data/Clock Complement

CD+

Signal Input USITT DMX512/AMX192

Data/Clock True

ANA

USITT AMX192 or D54 Analog Input (optional)

CONNECTOR J5

Analog Control Outputs

Min. 0 to +10V Max. 0 to +15V

Max. Drive 1mA

CONNECTOR J4

PIN

Aux. Control Outputs on 26 pin DIL header

1-24

Channels 1-24

25 & 26 Signal Common

PINOUT FOR DB25 CONNECTORS

1-12

Channels 1-12

13

Common

14-25

Channels 13-24

CONNECTOR LEGEND

OUTPUT VOLTAGE ADJUSTMENT

STATUS QUO HOLD TIME

S1-1

Disabled (2 Sec. timeout)

OFF

Enabled ( 5 Min. timeout)

ON

Maintains last dimmer levels for set time on loss of input data signal

TEST AND CALIBRATE MODE

S1-2

Disabled (Normal Operation)

OFF

When enabled allows analog dimmer outputs to be brought to full
one at a time as selected by the rotary address switches.

FUTURE USE

S1-3

DMX TERMINATION

S1-4

DMX Line Unterminated

OFF

DMX Line Terminated

ON

This switch connects a 100-ohm resistor across the DMX data pair.
The unit should be terminated if it is the last receiving device on the
DMX line, otherwise leave this switch OFF.

Enabled

ON

DIP Switch Settings

ADDRESS SELECTION

Three rotary switches select the offset start address for the unit
in most configurations. In test mode, the switches set dimmers
to full one at a time. The switches are set as (S4) hundreds,
(S3) tens and (S2) ones.

Two LEDs are used to indicate power supply and proces-
sor run status and data receive detection.

OUTPUT CONFIGURATION

Place the unit in test mode (S1-2 ON) and set the address
switches to 000 or 001. Ensure that the decoder is con-
nected to dimmer no. 1 and JP1 & JP2 are in the correct
position. Connect a DC voltmeter between COM and out-
put terminal no. 1 on the circuit board. Adjust P1 to
achieve the desired full on control voltage.

CAUTION – Disconnect power from the unit before
making any changes
For 4-12V output install JP2.
For 12-15V output remove JP2.
If J4 is used with a DB25 output connector, install JP1 to
reassign the analog output signals as shown in the Con-
nector Legend chart, otherwise DO NOT install JP1

rev.5 ver2.2 release2

05/03

Printed in Canada

[email protected]

www.pathwayconnect.com.com

GRAY

Pathway Connectivity, 480C - 36 Avenue S.E.,

Calgary, AB, T2G 1W4 Canada
tel (403) 243-8110 fax (403) 287-1281

RUN

Glowing steadily indicates power supply and
processor OK; off indicates no power, and flash-
ing indicates defective processor hardware.

RxD

Glowing steadily indicates data signal received;
off indicates no signal present. Note that an ad-
dress selection out of the range of the data signal
will extinguish the LED.

0.2500"

3.6750"

4.0750"

0.25

00"

4.50

00"

4.7

500"

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

LCDM

2

4 DECODER R

E

V

.5

9

93

5

S/N

SE

R

IA

L

#

Advertising