LCMX-64 ANALOG MULTIPLEXER Configuration

CONNECTOR DESIGNATION

One LED (LD1) is used to indicate power supply and processor run
status. Glowing steadily indicates power supply and processor OK.
Off points to defective or missing power supply, and flashing sug-
gests defective processor hardware.

LED INDICATOR

TEST POINTS

TP1 SCOPE SYNC. Use the test point to trigger an oscillo-
scope from the reset pulse of an AMX192 output or the
break signal of a DMX512 output.
GND Power supply and signal common

MODE SELECT

1

2

DMX512 OUTPUT 1-192

ON

ON

DMX512 OUTPUT 193-384

OFF

ON

AMX192 OUTPUT

ON

OFF

D54 OUTPUT

OFF

OFF

INPUT TRANSIENT FILTER

(ver.1.2 and later)

For use with contact closure inputs only

3

4

HIGH FILTER

ON

ON

LOW FILTER

ON

OFF

DISABLED

OFF

OFF

CHANNELCONFIGURATION

5

60/120/180 CHANNELS

OFF

64/128/192 CHANNELS

ON

OPERATING MODE

6

AMX OUTPUT CALIBRATE

OFF

NORMAL (RUN) MODE

ON

NUMBER OF CHANNELS

7

8

60/64 CHANNELS

ON

ON

120/128 CHANNELS

OFF

OFF

180/192 CHANNELS

OFF

OFF

DIP Switch Settings

CONNECTOR J1

PINS 1-32

Analog input signals 1-32

PINS 33-34 Analog signal common

CONNECTOR J2

PINS 1-32

Analog input signals 33-64

PINS 33-34 Analog signal common

CONNECTOR J3

LCMX64E EXPANSION CARD CONNECTOR

V+

Power supply input, +12-15VDC, 150mA

COM

Power supply common

ANA

AMX192/D54 analog output signal

CD-

AMX clock (-) or DMX512 data (-)

CD+

AMX clock (+) or DMX512 data (+)

CONNECTOR J4

03/03

Printed in Canada

[email protected]

www.pathwayconnect.com

GRAY

Pathway Connectivity, 480C - 36 Avenue S.E.,

Calgary, AB, T2G 1W4 Canada
tel (403) 243-8110 fax (403) 287-1281

J1

J2

J3 (1)

JP1

192

128

4.2500"

3.5000"

0.5000"

5.

0000

"

4.

7500"

0.

2500

"

V+

COM

COM
ANA
CD-

CD+

J1

J2

J3

P1

S1

TP1

GND/
COM

L1

J4

6.6000"

5.9000"

3.9000"

0.9000"

5.

0000

"

4.

7500"

0.

2500

"

LCMX64

LCMX64E

MAXIMUM INPUT VOLTAGE

Do not exceed 12VDC on any off the analog inputs.

OUTPUT CALIBRATE

AMX/D54 output level can be calibrated by turning S6 off and ad-
justing P1 while measuring the DC value at the ANA terminal on J4.

LCMX64E

The LCMX64 can support up to 192 channels with the addition of 1 or
2 LCMX64E expander cards. To install the LCMX64E, simply mount
each on top of the LCMX64 using min. 1” standoffs and connect the
cards together using the supplied 10 conductor ribbon cable. Ensure
that the total number of channels are set correctly on DIP switches 7 &
8 and at JP1 on each LCMX64E.