Dip switch settings & connector pinouts – Pathway # 8601, 8603, 8605 User Manual

Page 4

Advertising
background image

DIP SWITCH SETTINGS & CONNECTOR PINOUTS

WARRANTY

WARRANTY: Gray Interfaces products are carefully tested and inspected at the

factory and are warranted to be free from material and workmanship defects for a

period of one year from date of shipment. Seller's warranty shall be restricted to the

repair or replacement of any part that proves to be defective and for which a claim is

submitted to Seller before the expiration of the applicable warranty period, providing

that this warranty shall not apply to any defect arising from accident, misuse or

improper or unauthorized adjustment or repair. Seller will not assume any

responsibility for any labor expended or materials used to replace and/or repair any

equipment without Seller's prior written authorization. Freight terms on warranty

repairs are F.O.B. Seller's warehouse or factory. Collect shipments or freight

allowances will not be accepted without Seller's written authorization.

4

1 - COMMON
2 - CLOCK+
3 - ANALOG
4 - CLOCK-

1 - COMMON
2 - NC
3 - ANALOG

1 - COMMON
2 - DATA-
3 - DATA+
4 - NC
5 - NC

AMX - 192

STRAND D54 (384)

DMX - 512

IN (M)

OUT (M)

3

2

1

4

3

2

1

5

4

3

2

1

OUT (F)

IN (F)

5

4

3

2

1

PUSH

PUSH

4

3

2

1

PUSH

3

2

1

OPERATING MODE

STATUS QUO OPTION

CALIBRATE MODE

DUAL AMX OUTPUT

TEST CYCLE MODE

I/O MODE

S1-1

S1-3

S1-2

S1-5

S1-6

S1-7

S1-8

S1-4

BACKUP

STATUS QUO enabled

D/A OUTPUT CHECK enabled

DUAL AMX OUTPUT enabled

TEST CYCLE enabled

TEST CYCLE disabled

SINGLE AMX OUTPUT enabled

STATUS QUO disabled

D/A OUTPUT CHECK disabled

DMX input - DMX output

DMX input - AMX output

AMX input - AMX output

AMX input - DMX output

PILE-ON

MERGE

PM REV.6 9606

TEST MODE

ON

ON

OFF

ON

OFF

OFF

ON

OFF

ON

ON

ON

ON

ON

OFF

OFF

OFF

OFF

ON

ON

OFF

OFF

ON

OFF

OFF

A signal present on input A will have full control of the output, and any signal at

input B will be ignored. If the A signal is lost, the output will be controlled by

input B. The address switches will offset both inputs.

Output data remains active at last valid levels for 5 minutes

Analog output level (5.0V) can be checked at the AMX output (pin 3)

DC voltmeter; no other functions are active

using a

Ramps the selected dimmer up and down continuously between zero and

full when in test mode

The selected dimmer is set to full when in test mode

Output data fails 2 seconds after loss of input data

Signals present at both inputs will have control of the output. The highest level

on any individual device channel on either input will be in control of the output

level. The address switches will offset both inputs.

Input B is appended to input A to create one continous output consisting of the

total numer of device channels on both inputs. The address switches will offset

input B only.

INPUT TEST: Receive data LEDs indicate correct data signal (on steady), faulty

or incorrect signal (flashing), or absence of any signal (off).

OUTPUT TEST: The selected protocol is transmitted and the device channel

assigned by the address switches is set to full or cycled as per switch S1-8.