Configuration & dip switch settings – Pathway #8721, 8723, 8725, 8741, 8743, 8745 User Manual

Page 4

Advertising
background image

CONFIGURATION & DIP SWITCH SETTINGS

TEST AND CALIBRATE MODE

STATUS QUO HOLD TIME

PROTOCOL SELECT

DMX TERMINATION

WARRANTY

1

2

3

4

DISABLED (2 SEC TIMEOUT)

DISABLED (NORMAL OPERATION)

AMX-192 or D54

DMX LINE UNTERMINATED

ENABLED (5 MIN TIMEOUT)

ENABLED

DMX-512

DMX LINE TERMINATED

OFF

OFF

OFF

OFF

ON

ON

ON

ON

Maintains last dimmer levels for set time on
loss of input data signal.

WARRANTY:

Gray

Interfaces

products

are

carefully tested and inspected at the factory
and are warranted to be free of material and
workmanship defects for a period of six months
from date of shipment. Seller's warranty shall be
restricted to the repair or replacement of any
part that proves to be defective and for which a
claim is submitted to Seller before the expiration
of the applicable warranty period, providing
that this warranty shall not apply to any defect
arising

from

accident,

misuse

or

improper

installation or unauthorized adjustment or repair.
Seller will not assume any responsibility for any
labour expended or materials used to replace
and/or repair any equipment without Seller's
prior written authorization. Freight terms on
warranty repairs are F.O.B. Seller's warehouse or
factory. Collect shipments or freight allowances
will not be accepted without Seller's written
authorization.

4

When

enabled

allows

analog

dimmer

outputs to be brought to full one at a time
as selected by the rotary address switches.

OUTPUT VOLTAGE ADJUSTMENT (all models)

Remove the six screws from the top cover of the decoder unit,place the unit in
test mode (S1-2 on) and set the address switches to 000 or 001. Ensure that the
decoder is connected to dimmer no. 1 and connect a DC voltmeter between
COM and output terminal no. 1 on the circuit board. Adjust P1 to achieve the
desired control voltage.

OUTPUT CONNECTOR ASSIGNMENT (all models)

If your decoder uses 25-pin D-type output connectors, you must install JP1 on 24
channel units or JP3 on 48 channel units. This will reassign the output control
signals to conform to the analog pin assignment detail on page 3.

OUTPUT CONFIGURATION (48 channel models)

OUTPUT CONFIGURATION
(24 channel models)

CAUTION - Disconnect power from the unit before making any changes!
For 10V systems, JP1 and JP2 are installed; remove them for 15V systems. For
positive outputs, jumper pins 2 and 3 of JP4, 5 and 6, and install diode packs DP1-
6 with the notch facing down. For negative outputs, jumper pins 1 and 2 of JP4, 5
and 6, and install the diode packs with the notch facing up. Before powering up,
check to make sure that all jumpers are installed correctly. Damage will result if
the unit is powered up with any jumpers in the wrong position.

For 10V systems, JP2 is installed and
JP3,

JP4

are

removed.

For

15V

systems, JP2 is removed and JP3, JP4
are installed.

This switch is active only on 48 channel
models.

A 100-ohm resistor is connected across the
DMX data pair. Unit should be terminated if
it is the last receiving device on the DMX
line.

JP4

DP1

DP2

DP3

DP4

DP5

DP6

JP1

JP1

JP4

JP3

JP2

P1

JP2

JP3

JP6

JP5

123

123

123

P1

48 CHANNEL DECODER CARD

24 CHANNEL DECODER CARD

Advertising