Configuration & dip switch settings – Pathway #8721, 8723, 8725, 8741, 8743, 8745 User Manual
Page 4
CONFIGURATION & DIP SWITCH SETTINGS
TEST AND CALIBRATE MODE
STATUS QUO HOLD TIME
PROTOCOL SELECT
DMX TERMINATION
WARRANTY
1
2
3
4
DISABLED (2 SEC TIMEOUT)
DISABLED (NORMAL OPERATION)
AMX-192 or D54
DMX LINE UNTERMINATED
ENABLED (5 MIN TIMEOUT)
ENABLED
DMX-512
DMX LINE TERMINATED
OFF
OFF
OFF
OFF
ON
ON
ON
ON
Maintains last dimmer levels for set time on
loss of input data signal.
WARRANTY:
Gray
Interfaces
products
are
carefully tested and inspected at the factory
and are warranted to be free of material and
workmanship defects for a period of six months
from date of shipment. Seller's warranty shall be
restricted to the repair or replacement of any
part that proves to be defective and for which a
claim is submitted to Seller before the expiration
of the applicable warranty period, providing
that this warranty shall not apply to any defect
arising
from
accident,
misuse
or
improper
installation or unauthorized adjustment or repair.
Seller will not assume any responsibility for any
labour expended or materials used to replace
and/or repair any equipment without Seller's
prior written authorization. Freight terms on
warranty repairs are F.O.B. Seller's warehouse or
factory. Collect shipments or freight allowances
will not be accepted without Seller's written
authorization.
4
When
enabled
allows
analog
dimmer
outputs to be brought to full one at a time
as selected by the rotary address switches.
OUTPUT VOLTAGE ADJUSTMENT (all models)
Remove the six screws from the top cover of the decoder unit,place the unit in
test mode (S1-2 on) and set the address switches to 000 or 001. Ensure that the
decoder is connected to dimmer no. 1 and connect a DC voltmeter between
COM and output terminal no. 1 on the circuit board. Adjust P1 to achieve the
desired control voltage.
OUTPUT CONNECTOR ASSIGNMENT (all models)
If your decoder uses 25-pin D-type output connectors, you must install JP1 on 24
channel units or JP3 on 48 channel units. This will reassign the output control
signals to conform to the analog pin assignment detail on page 3.
OUTPUT CONFIGURATION (48 channel models)
OUTPUT CONFIGURATION
(24 channel models)
CAUTION - Disconnect power from the unit before making any changes!
For 10V systems, JP1 and JP2 are installed; remove them for 15V systems. For
positive outputs, jumper pins 2 and 3 of JP4, 5 and 6, and install diode packs DP1-
6 with the notch facing down. For negative outputs, jumper pins 1 and 2 of JP4, 5
and 6, and install the diode packs with the notch facing up. Before powering up,
check to make sure that all jumpers are installed correctly. Damage will result if
the unit is powered up with any jumpers in the wrong position.
For 10V systems, JP2 is installed and
JP3,
JP4
are
removed.
For
15V
systems, JP2 is removed and JP3, JP4
are installed.
This switch is active only on 48 channel
models.
A 100-ohm resistor is connected across the
DMX data pair. Unit should be terminated if
it is the last receiving device on the DMX
line.
JP4
DP1
DP2
DP3
DP4
DP5
DP6
JP1
JP1
JP4
JP3
JP2
P1
JP2
JP3
JP6
JP5
123
123
123
P1
48 CHANNEL DECODER CARD
24 CHANNEL DECODER CARD