MEGUIAR'S M03 User Manual

Page 4

Advertising
background image

M03, Machine Glaze (original formulation): M0316, M0364

__________________________________________________________________________________________

Page: 4 of 14

6.4. Reference to other sections
Refer to Section 8 and Section 13 for more information

SECTION 7: Handling and storage

7.1. Precautions for safe handling
For industrial or professional use only. Do not handle until all safety precautions have been read and understood. Do not
breathe dust/fume/gas/mist/vapours/spray. Do not get in eyes, on skin, or on clothing. Do not eat, drink or smoke when
using this product. Wash thoroughly after handling. Avoid contact with oxidising agents (eg. chlorine, chromic acid etc.)
Use personal protective equipment (eg. gloves, respirators…) as required. Vapours may travel long distances along the
ground or floor to an ignition source and flash back.

7.2. Conditions for safe storage including any incompatibilities
Store away from areas where product may come into contact with food or pharmaceuticals. Store away from acids. Store
away from oxidising agents.

7.3. Specific end use(s)
See information in Section 7.1 and 7.2 for handling and storage recommendations. See Section 8 for exposure controls and
personal protection recommendations.

SECTION 8: Exposure controls/personal protection

8.1 Control parameters

Occupational exposure limits

Ingredient

CAS Nbr

Agency

Limit type

Additional comments

Silica, crystalline (airborne
particles of respirable size)

14464-46-1 Health and

Safety Comm.
(UK)

TWA(respirable):0.1 mg/m3

Glycerin

56-81-5

Health and
Safety Comm.
(UK)

TWA(as mist):10 mg/m3

Silica, amorphous

68855-54-9 Health and

Safety Comm.
(UK)

TWA(as inhalable dust):6
mg/m3;TWA(as respirable
dust):2.4 mg/m3

Paraffin Wax

8002-74-2

Health and
Safety Comm.
(UK)

TWA(as fume):2
mg/m3;STEL(as fume):6
mg/m3

Health and Safety Comm. (UK) : UK Health and Safety Commission
TWA: Time-Weighted-Average
STEL: Short Term Exposure Limit
ppm: parts per million
mg/m³: milligrams per cubic metre
CEIL: Ceiling

8.2. Exposure controls

8.2.1. Engineering controls
Use general dilution ventilation and/or local exhaust ventilation to control airborne exposures to below relevant Exposure
Limits and/or control dust/fume/gas/mist/vapours/spray. If ventilation is not adequate, use respiratory protection equipment.

8.2.2. Personal protective equipment (PPE)

Eye/face protection

Advertising