1. Position the Brute Terminal Crimper base down on a

solid, level surface, such as a sturdy work bench.

2. Open the crimper. With your thumb on the thumb rest

on the top of the tool, hook your index finger under the
lift pin and pull upward. Note: The Brute can be locked
in the open position by moving the pin to the left or right
while open.

3. Insert terminal or splice in nest as illustrated.

A. Terminals - Center crimp barrel in nest.
B. Splice Connectors - Center one half of crimp barrel

in nest. After crimping, center the other half of the
crimp barrel in nest.

4. Release ram from locked open position. This will

secure the terminal in the Brute.

5. Insert stripped wire into barrel of terminal or connector.

Before inserting cable, be sure to install protective
products such as terminal protectors and heat shrink
tubing.

6. Strike ram firmly with a large hammer until cable is

secure. Use scale on ram as a guide.

7. Lift ram and remove completed termination.

8. Tool is designed to prevent over crimping. Crimping can

also be accomplished by closing tool in a vise.

9. For sustained operating life ram should be oiled occa-

sionally with light machine oil.

A.

Always wear safety glasses when

using a hammer or working around

a battery.

B.

Make sure hands are free of tool

when crimping.

C.

Do not use the Brute Terminal

crimper on live electrical cable. Dis-
connect power before crimping.

Brute Hammer Crimp Tool

Instructions

The Brute is engineered to crimp electrical terminals on

stranded copper cable. Suitable for all wire sizes from

16 gauge to 4/0 gauge.

F252a