SYMPTOM

Fan will not start
SOLUTION
Check to make sure the wall switch is turned on.
Check circult fuses or breakers.
Caution! Make sure the power is turned off before performing the

following steps.

Remove canopy and check wire connections.
Check wall control transmitter connections(if applicable).
Note:fan must be installed at a maximum distance of 40 feet from

the transmitting unit for proper signal transmission between the
transmitting unit and the fan’s receiving unit.

SYMPTOM
Fan Sounds Noisy
SOLUTION
Allow a 24 - hour “ break in ” period. Most noises associated

with a new fan will go away during this time.

Make sure the screws that attach the fan blade holder to the

motor hub is tight.

Make sure outlet box is secured to building structure, if

necessary use the wood screws provided to fruther secure
outlet box to joist.

Make sure hanger bracket is secure to the outlet box,screws are

tight.