SYMPTOM

Lights shut off andwill

not come back on.

SOLUTION

1. This unit is equipped

with a wattage limiting

device. Lamping in exc-

ess of 190 wvatts will

disable your ceiling fan’s

light kit. To reset your

light kit you must turn

the power off and rela-

mp, keeping the watta-

ge under 190 watts.

Restore power to your

ceiling fan and contin-

ue normal operation.

SYMPTOM

Frequency interference

SOLUTION

1.Turn the power off to your ceiling fan.

2.lease use a small size tool to change the frequency setting on the control system.

3.Return power to the unit Note: After the AC power is on,do not press any other

button on the transmitter before pressing the “Stop” button, doing so will cause the

procedure to fail.

4.Within 60 seconds of turning the Fan’s AC power ON.Press the transmitter’s Stop”

button for 10 seconds.

5.Once the receiver has detected the set frequency, the down light of your fan if

applicable will blink twice. (there is no indication if your fan is not equipped with

a light).

6.The receiver has now learn the frequency which has been selected on the transmitter.

After completing the steps above, you should be able to operate the ceiling fan and

light. If the fan is not responding to the transmitter, please turn the power off to

the receiver, and repeat the process.