background image

Air-Oil Tank Installation Instructions

CAA & CSA Self-Compensating and
AA & SA Adjustable 2” & 3” Bore Series

AIR-OIL TANK INSTALLATION (Figure 1)
Self-compensating models CAA and CSA as well as
adjustable models AA and SA are pre-filled with ATF
but

must be connected to an air-oil tank before use.

Install the proper ACE air-oil tank as close as possible to,
and physically higher than the shock absorber. The line
connecting the shock absorber to the air-oil tank must
be free of kinks and loops. The inside diameter of this
line must be equal to, or greater than, that of the port
in the shock absorber.
Do not put a shut-off valve between the shock
absorber and the air-oil tank.
Install a check valve in
the air line to the air-oil tank and plug the extra ports of
the tank. Fill the tank with ATF to the fill mark and charge
the system to between 50 - 100 psi (3.4 - 6.8 bar).

AIR EXHAUST CIRCUIT FOR MODELS CAA and
AA SHOCK ABSORBERS (Figure 2)
If the rod is to remain in the shock absorber after
decelerating the load, this type of installation is
necessary. Avoid overfilling the air-oil tank. If not built in,
a special ACE check valve should be used to eliminate
misting of oil out of the air-oil tank.

PROPER AIR-OIL TANK SIZE
Refer to the chart below for proper air-oil tank size.

Maximum efficiency of operation can be obtained by
carefully following these instructions:

23435 Industrial Park Drive
Farmington Hills, Michigan 48335
tel:

248.476.0213

fax:

248.476.2470

www.acecontrols.com

Bore

2”

3”

Air-Oil
Tank

AO-6-91

AO-6-91

Air-Oil Tank

(Re-circulating Circuit)

AO-6-91

AO-6-91

Figure 1

R

Fill Plug

Air-Oil Tank

Plug

Plug

Check Valve

above this line

Do not fill

WARNING

Do not use near open flame
contents may be flammable

Free

Flow

Inlet Port

Figure 2

Air-Oil Tank

above this line

Do not fill

Do not use near open flame
contents may be flammable

WARNING

CV 3/4-F

T

R

T

3-Way Normal
Closed Valve

F

SOL

Exhaust

Supply

World leader in deceleration technology
ISO 9001:2000 Certified

ACE Controls Inc.

Advertising