Dialog User Level (continued)

Dialog
item

Value

Function/Description

Only models with analog output:

*

0 ... xxx

Scale the analog output - start value (e. g. 0 bar = 4 mA)

*

0 ... xxx

Scale the analog output - end value (e. g. 400 bar = 20 mA)
(output signal start value always corresponds to the display initial value, e. g. 0
bar = 4mA)
Maximum turn-down 4 : 1, i.e. at values below 25 % of the measuring range
the analog output is switched off

0 ... xxx

Display of peak value „Max“ (xxxx: = max. 125 % f. s.)

Delete the maximum value memory

= no deletion

= delete value

Error display:

= no error

= exceeding pos. measuring range

= exceeding neg. measuring range

= sensor error

= error switching output 1

= error switching output 2

= data error (EEProm)

= program error

= calibration error

= error analog out

IMPORTANT

When changing units from psi to bar or bar to psi, the switching point values must be changed
accordingly.

* Flashing of the mean segment signals a negative setting value.

Operating Instructions

Dual pressure switch Switch 2000

Dual Temperature Switch TempSwitch 2000

1

Intended Applications .................................................................................................... 2

2

Safety Instructions ......................................................................................................... 2

3

Standards ........................................................................................................................ 3

4

Warranty/Guaranty ......................................................................................................... 3

5

Installation/Commissioning .......................................................................................... 3

6

Maintenance/Cleaning ................................................................................................... 4

7

Technical Data ................................................................................................................ 5

8

Operation......................................................................................................................... 6

9

Programming .................................................................................................................. 6

10

User Level Dialog Switch 2000/TempSwitch 2000 ...................................................... 7

Barksdale GmbH

Dorn-Assenheimer Straße 27

D-61203 Reichelsheim

Tel.:

+49 (6035) 949-0

Fax:

+49 (6035) 949-111 and 949-113

email: [email protected]

Internet: www.barksdale.de

1

8

Art. no.: 923-1440

Index N, 24.03.2010

Software-Version: V 2.1 and higher

Specifications are subject to changes
without notice!