Barksdale Series 20415 User Manual

Page 11

Advertising
background image


Barksdale, Inc. 3211 Fruitland Avenue, Los Angeles CA 90058 (800)835-1060 www.barksdale.com Bulletin No. 272367-B, 4-3-14

11

5. Insert bottom flange(43) first (except for configurations where bottom flange is part of the regulator body)
6. Insert bottom flange bolts(22) by hand (do not tighten yet)
7. Insert slide(2) and piston assembly(2,12) from top face
8. Insert the piston gland(14)
9. Insure up-down movement of slide by hand to make sure it travels freely
10. Tighten the bolts(22) at the bottom flange(43) (except for configurations where bottom flange is part of the

regulator body)

11. Insure slide movement is smooth inside gland and bushing
12. Install ALL flanges: Starting with the outlet(43) than the inlet/vent(36) *Verify orientation, inlet port top side

and vent port bottom side of flange*. Then Proceed to tilting the regulator so that the inlet(36) flange is laid
down to prevent the PRESSURE SEALS(6, 7) from falling when installing the blind(47) flange.

13. Tighten bolts (22) on all flanges and spring housing to 192-240 in-lbs.
14. Place spring housing assembly(16) into place and tighten the spring housing bolts (22)
15. Turn handle(29) all the way in (preload compression spring 3-4 turns clockwise)

Assembly is complete

8.0 TRANSPORT / STORAGE

Severe shock and vibration should be avoided during transport. Store it in a clean and dry environment.
Regulator is ready for operation upon delivery. The protective port plugs should not be removed until
immediately before connecting plumbing the regulator. To avoid damaging regulator or/and pilot motor, do
not lift or carry by the handle.

It is recommended to transport it with the lifting equipment suitable for the weight to be moved. Do not hook-up
lifting equipment to accessory such as handle, or pressure bores. When using a suspension belt it must be
placed around the regulator body, providing edge protection and ensuring weight distribution.
Transport/storage temperature is recommended to be between -40° C (-40° F) to +93°C (200°F). Protect
existing sealing surface on the connections from damage. Do not damage the corrosion protective layer.

9.0 DISPOSAL / RETURNS

Regulator that has come in contact with health – threatening media must be decontaminated prior to disposal
or returned to Barksdale.
Follow proper Federal/ State and local regulations for appropriate disposal to protect the environment.


















Advertising