8.0 TROUBLE-SHOOTING

Caution:

Table 4 is used as a quick trouble shooting tool and mainly for reference only. It does not mean to

list all possible causes and solutions to the problems as seen by the user on Regulator. Contact factory or
authorize dealers for technical support and issues.

Table 4.

PROBLEM 

POSSIBLE CAUSE 

SOLUTION / RECOMMENDATION 

Handle 
does not 
move 

Outlet port line has pressure restrictions.

Refer sales drawing for outlet pressure range. 

Vent port has restrictions. 

Connect Vent port line to atm tank. 

No 
Actuation 

No pilot pressure 

Provide pressure to pilot line 

Pilot line pressure blocked 

Only one pilot port may be pressurized at a time. 

Locking handle not tight. 

Tighten handle with rubber mallet. 

Pilot line leaking 

Tighten or replace pilot line. 

External 
leakage 

Loose connections 

Tighten connections. 

Exceeding maximum working pressure 

Refer to data sheet 

Internal 
leakage 

Wear/Tear of pressure seals and O rings 

Replace with new Seals and O‐Rings. 

8.1 MAINTENANCE INSTRUCTIONS

CAUTIONS
All repair of Barksdale ShearSeal® Regulators should be performed in a clean area free of excess dirt
and debris. The ShearSeal® components are manufactured to precise tolerances and can be
damaged if proper care is not taken.

WARNING
Isolate the regulator from all system pressure before performing any disassembly procedures.

Exploded view provided by Barksdale and/or distributor for reference only. It is strongly recommended that

all repairs and kit installations are completed by appropriately trained personnel. The customer will assume all
risk associated with the use of unauthorized parts or personnel.