Technical specifications – APTech Series VS1000 User Manual

Page 5

Advertising
background image

VS1000 Manual

P/N 00-15000009 Rev 0

Page 5 of 8

3. TECHNICAL SPECIFICATIONS

3.1.1. Marking

The VS1000 is marked with the following information:

Model number

Maximum inlet pressure

Maximum outlet pressure

Serial number

“HP” at high-pressure (inlet) ports

“LP” at low-pressure (outlet) ports

Note: Arrows are sometimes used to point from the “HP” or “LP” text to designate more than one
high-pressure or low-pressure port.

3.1.2. Physical (refer to catalog data sheet or contact AP Tech for more detailed information)

Standard regulator body dimensions are approximately 2 inch (51 mm) diameter by 6 inch

(152 mm) high. Standard steam tube dimensions are 9 inch (229 mm) long and located 1 inch
(25.4 mm) above the base of the regulator.

Weight is approximately 2.5 lbs (1.13 kg).

Standard mounting of regulator is by 2 each 10-32 threaded, 0.25 inch (6.3 mm) deep holes

located in the bottom of the regulator on either side of the standard inlet port. Alternately, the
inlet and outlet connections can be used to secure the regulator if the connections are of
appropriate size and strength, and properly supported.

3.1.3. Porting

Standard inlet: 1/8-27 NPT female

Standard outlet: 1/4-18 NPT female

Optional porting configurations available

3.1.4. Standard Pressure Ratings

3500 psig (241 bar) maximum inlet pressure

30 psig (2.1 bar), 100 psig (6.9 bar), 250 psig (17.2 bar), and 500 psig (34.5 bar) maximum outlet

pressure options (specified when ordered)

Optional pressure ranges available

3.2. Facility

Requirements

The following is needed to install the VS1000 at the users facility.

Steam supply and return lines

Mounting brackets

Appropriate pipe or tube fittings

Teflon® thread tape (pipe dope sealants are not recommended as some types can leach impurities

into the process fluid lines or may react with the process fluid)

Various tools

Advertising