After the unit is operating properly, a performance
test should be considered. If a performance test is
conducted when the pump is new, subsequent tests
can be used to determine the degree of wear or
deterioration of the pump without removing it from
the well. After the unit has been in operation for
approximately one week, perform the routine tests.

SECTION 7 – PUMP DISASSEMBLY

AND REASSEMBLY

7-1 Clear a large area adjacent to the pump
as storage space for pump parts as they are
disassembled. If the pump has a long column,
arrange parallel timbers on the ground to support
the pump column horizontally. After disassembly
for repair or replacement of pump components,
reassemble in all cases in the reverse order of
disassembly.

NOTE

PUMP COMPONENTS SHOULD BE MATCH-

MARKED PRIOR TO DISASSEMBLY.

7-2 It is recommended that maintenance person-
nel become thoroughly familiar with the VS pump
before performing any removal of the components.
Consult the manufacturer’s instructions for
detailed disassembly information for the motor.

A. Remove the electrical connection at the con-

duit box and tag electrical leads at the motor.

WARNING

BEFORE OPENING THE CONDUIT BOX OF AN

ELECTRICAL MOTOR, BE SURE THE CURRENT

TO THE MOTOR IS SHUT OFF. SEVERE INJURY

TO PERSONNEL COULD RESULT IF CONTACT

WITH LIVE MOTOR LEADS IS MADE

LOCK OUT SHOULD BE INSTALLED BEFORE

ANY ELECTRICAL WORK IS PERFORMED

NOTE

MATCH-MARK PARTS IN SEQUENCE OF

DISASSEMBLY TO AID IN THE REASSEMBLY

PROCEDURE.

B. Disconnect the discharge piping from well head.

WARNING

DO NOT WORK UNDER A HEAVY SUSPENDED

OBJECT UNLESS THERE IS A POSITIVE SUP-

PORT UNDER IT WHICH WILL PROTECT PER-

SONNEL SHOULD A HOIST OR SLING FAIL.

7-3 PUMP DISASSEMBLY

In the following pump disassembly procedures
references are made to installation sections of

this manual, these sections will aid in the disas-
sembly of the pump.

Fig 7.1 Bowl and Motor Assembly

9