8 troubleshooting – Nilfisk-ALTO NEPTUNE 8 User Manual

Page 18

Advertising
background image

16

english

1)

Options / model variants

NEPTUNE 5 / 7 / 8

Indication

on Display

Cause

Remedy

FLF

FLF

>

Flow sensor fault

Contact Nilfi sk-Alto Service
Cold water operation possible

FLO

FLO

>

Water supply turned off or inadequate supply
to machine

Required volume fl ow and pressure see
chapter 9.3 Technical Data

>

Detergent tank empty

Fill detergent tank or set detergent me-
tering to „OFF“

>

Pressure regulation on the safety control
block or VarioPress-lance

1)

set to low water

volume

Turn the twist grip on safety control block
or VarioPress-lance

1)

to higher water/

pressure volume (see chapter 4.4)

>

Machine scaled

Contact Nilfi sk-Alto Service

Fue

Fue

>

Fuel shortage

Fill fuel tank
Cold water operation possible

Hop

Hop

>

Motor overheated

Turn main switch in position „OFF“, let
machine cool down

Remove extension cord, if being used.

Possible phase failure; have electrical
connections checked

HOS

HOS

>

Machine overheated

Contact Nilfi sk-Alto Service

LEA

LEA

>

Leakage or inadmissible operating condition
by short-time operation

After three times of short-time ope ration
the machine switches off. To reset: Turn
main switch to position “OFF“, then start
again. Keep trigger squeezed for longer
than 3 seconds. If a leak occurs in the
hose and gun and causes the machine
to start and stop briefl y 3 times, then the
machine will switch off.

>

Spray gun leaking

Repair Spray gun

>

High pressure hose, coupling or line system
leaking

Replace high-pressure hose, retighten
screw fi ttings

>

Detergent tank empty

Fill detergent tank or set detergent me-
tering to „OFF“

>

Water inlet fi lter dirty

Clean fi lter (see chapter 7.2.1)

>

High-pressure pump drawing in air

Repair leaks

LHE

LHE

>

Flame sensor sooted

Clean flame sensor (see chapter
7.2.6).

>

Ignition or fuel system failure

Contact Nilfi sk-Alto Service
Cold water operation possible

LHL

LHL

>

Burner failure

Contact Nilfi sk-Alto Service
Cold water operation possible

POL

POL

>

Pump oil low

Fill to proper level (see chapter 7.2.3)

SEC

SEC

>

Temperature sensor damaged

Contact Nilfi sk-Alto Service
Cold water operation possible

SEO

SEO

>

Temperature sensor damaged

Contact Nilfi sk-Alto Service
Cold water operation possible

UPC

UPC

>

Microprocessor failure

Contact Nilfi sk-Alto Service

8 Troubleshooting

8.1

Indications on Display

Advertising