1. Disconnect electrical power

to the furnace and shut off
water supply.

2. Disconnect the water line at

the inlet compression nut.

3. Remove the in-line strainer

from inside the inlet side of
the valve by using a small
nail or wire.

4. Flush the in-line strainer

clean or replace with a new
strainer, Service Department,
Part No. 4004.

5. Replace the in-line strainer

and reconnect the inlet water
line. (Double Wrench To
Prevent Leaking.)

6. Disconnect the water line at the outlet compression nut.

7. Remove the orifice from the copper or plastic tube and make sure

this small opening is unplugged.

8. Replace the orifice and reconnect the outlet water line.

(Double Wrench To Prevent Leaking.)

9. Turn on water supply and reconnect electrical power to

the furnace.

OUTLET
COMPRESSION
NUT

ORIFICE

INLET

INLET
COMPRESSION
NUT

SOLENOID
VALVE

IN-LINE
STRAINER

INSPECTION AND SERVICE INSTRUCTIONS

NOTE: Periodic inspection and preventive maintenance of your total
heating system is important for efficient and safe operation. Your heating
contractor should include humidifier service at the same time.

All models are equipped with an in-line water strainer and orifice as
shown below. These parts should be inspected and cleaned periodically to
assure continued proper unit performance.

VIII. PERIODIC PREVENTATIVE MAINTENANCE