Connection – Australian Monitor ICON 3 User Manual

Page 5

Advertising
background image

Shown with

locking clip

facing

White/Green 1

Green 2

White/Orange 3

Blue 4

White/Blue 5

Orange 6

White/Brown 7

Brown 8

568A configuration

CABLE

1

CN1

This RJ45 connector provides power, data and audio signals to and from the
ICON-3, for direct connection to the Zone Revolution Page ports.

Each ICON-3 paging station is connected directly to the Zone Revolution in
a point-to-point manner. Zone Revolution supports a maximum of 2 ICON-3
stations.

When wiring the ICON-3 paging stations we suggest using straight-through
pre-made cables wherever possible. If the termination of new installed cable
is required, ensure both ends of the CAT5 cable are terminated for the 568A
configuration as per the wiring diagram right.

WARNING: It is not possible to route this connection through network
switches or any other equipment, doing so may damage all connected
equipment. Only direct pin-for-pin copper connections are supported.

Powering The Icon-3

The ICON-3 paging stations obtain their power source from the Zone Revolution
and do not require any other connection..

1

PAGE 5

ICON-3 MANUAL

CONNECTION

Advertising