Icon-cp and in600 – Australian Monitor ICON CP User Manual

Page 6

Advertising
background image

1. Source 1 (DVD1)

1. Projector On

1. Projector On

2. Source 2 (DVD2)

2. Projector Off

2. Projector Off

3. Source 3 (AUX1)

3. Mic 1 On

3. Mic 1 Off

4. Source 4 (AUX2)

4. Mic 2 On

4. Mic 2 Off

5. Source 5 (PC1)

5. Mic 3 On

5. Mic 3 Off

6. Source 6 (PC2)

6. Mic 4 On

6. Mic 4 Off

7. Source Volume Up

7. Mic Volume Up

7. Mic Volume Up

8. Source Volume Down

8. Mic Volume Down

8. Mic Volume Down

With the ICON-CP’s DIP switch bank 2(FUNC) set with D on the ICON-CP will control the
AMAV IN600.

The control parameters are fi xed to three different confi gurations. These are:

Address ID 1: (Switch 1 On)

With this setting you get control over selection of the sources and also volume control
of the source mixer. When a source is selected after already being active the unit will
switch the source to “Off”

Address ID 2: (Switch 2 On)

With this setting you have control over turning the projector on and off. You can also turn
each microphone on by triggering its mute control. The volume control will control the
mic mixer level on the unit.

Address ID 3: (Switch 1 and 2 On)

With this setting selected you have the exact same controls as ID2 except the
microphone mute controls are inversed so that the active state will have the
microphone off.

Powering the ICON-CP

The ICON-CP remote panels will need to be externally powered when being used with
the IN600. As these units have RJ45 looped in and outs we now provide a 24V DC
power injector that simply has a data in and a P+Data out. It is recommended that this
unit be placed close to the ICON-CP, all you need to do is run from the IN600 into the
power injector then out to your run of remote panels.

Connecting to the IN600

When wiring the ICON-CP panels we suggest simply using premade cables if possible
or if terminating your own to follow one standard the whole way that will allow your
connections to be pin to pin from the start to the end.

The IN600 has a terminal block for the RS485 bus. The pin out needed to connect the
ICON-CP to the IN600 is below:

Data line A = Pin 3 of the ICON-CP

Data line B = Pin 6 of the ICON-CP

Gnd line = Pin 2 of the ICON-CP

Shown with

locking clip

facing

White/Green 1

Green 2

White/Orange 3

Blue 4

White/Blue 5

Orange 6

White/Brown 7

Brown 8

568A configuration

CABLE

Address ID 1: (Switch 1 On)

Address ID 2: (Switch 2 On)

Address ID 3: (Switch 1 and 2 On)

PAGE 6

ICON-CP MANUAL

ICON-CP AND IN600

Advertising