Î

CHANGING ROTATION

Series HSC and HSC-S centrifugal pumps can be operated

Ê

left hand or right hand when viewed from the pump end of the

Ê

pump. If you wish to reverse the suction and discharge

Ê

nozzles, this can be accomplished with the same pump as

Ê

follows:

Ê

IMPORTANT: Refer to the disassembly and assembly proce-

Ê

dures section of this manual for proper disassembly and

Ê

assembly techniques:

Ê

1. Remove the impeller from the shaft, turn it 180° and replace

Ê

it on the shaft. (NOTE: Impeller can only come off from the

Ê

outboard end.)

Ê

2. With the rotating element out of the casing, remove the

Ê

casing from the bedplate and turn 180°.

Ê

3. Set the rotating element back in the casing and reassemble

Ê

the pump.

Ê

NOTE: The impeller and casing are in the same relationship

Ê

to each other as they were originally. The shaft and motor

Ê

are also in the same relationship to each other as they were

Ê

originally.

Ê

4. Reassemble pump and realign the coupling as called for in

Ê

the alignment instructions.

Ê

5. The rotation of the motor must be changed by switching the

Ê

motor leads.

Ê

NOTE: Unless the motor rotation is reversed, the impeller

Ê

will run backward.

Ê

WARNING: Rotating Components Hazard
Do not operate pump without all guards in place.

Ê

Failure to follow these instructions could result in serious

Ê

personal injury or death and property damage.

Ê

ROTATION

ROTATION

DISCHARGE

DISCHARGE

SUCTION

LEFTHAND ROTATION VIEWED

FROM THE PUMP END

RIGHTHAND ROTATION VIEWED

FROM THE PUMP END

Illustration 9 – Correct Relationship of Impeller and Casing

13

5

1

9

15

7

3

11

16

8

4

12

14

6

2

10

Illustration 10 – Main Joint Bolts